PDW90 Point to Multi-Point Wireless Instruction Manual
32
Entering Numeric Values
Numeric values are set using the
next
and
previous
buttons. Press
next
to select next digit and
previous
to increment digit value.
The selected digit will flash.
Press the
enter
button, at any time, to accept the value or the
menu
button to exit without saving.
Network ID
The
Network ID
is the unique network identifier that allows all field units to connect to the base station.
The ID can be set to any number between
01
and
99
. All field units must be set to the same
Network ID
as the base station in order to communicate. Multiple field unit/base station pairs may be installed within
range of each other by setting unique
Network ID
s.
Modbus Address
The
Modbus Address
is used to identify each individual field unit connected to the point-to-multipoint wire-
less network. The Modbus address can be any number between
001
and
247
. This address must be
unique among all field units on the same
Network ID
. This address must also be unique among all other
Modbus devices connected to the network.
Password Setup
The wireless field units may be protected with a four-digit numeric password in order to prevent unauthor-
ized tampering. When a password has been set, you will be prompted to enter that password in order to
access the device menu.
To disable password protection, simply set
0000
as the password.
NOW: 01
NETWORK ID
SET: 01
NETWORK ID
SET: 11
NETWORK ID
SET: 11
NETWORK ID
SET: 12
NETWORK ID
Access
edit mode
Increment
selected digit
Select the
next digit
Increment
selected digit
Accept
new value
SETUP
PASSWORD
NOW: 0000
PASSWORD (0=OFF)
SETUP MENU
BACK TO
SET: 0123
PASSWORD (0=OFF)
increments selected digit.
selects next digit to the right.
0000
disables the password.
www.
.com