Advanced Configuration
Device communication can be secured by enabling 128-bit AES encryption. A channel mask may also be
set for interference immunity. The encryption key and channel mask may be entered on the
Advanced
tab. Once you have entered the encryption information, click
Save Settings
. If you have made changes
that have not been saved and would like to load the saved settings from the base station, click the
Read
Settings
button.
The wireless field units must share identical encryption keys in order to communicate with the base sta-
tion, so be sure to enter the same information for all of the field units. See Programming the Field Units
with PDW Manager on page 34 for information on programming the field units.
If you would like to reset the base station to factory default settings, click the
Reset all system parameters
to Factory Defaults
button. All field units may be cleared from the client database by clicking the
Clear Cli-
ent Database