Owner’s Manual for Portable Generator
17
Service Spark Plug
To service spark plug:
1. Clean area around spark plug.
2.
3.
Remove and inspect spark plug.
I
n
spect electrode gap with wire feeler
gauge and reset spark plug gap to 0.028
-0.031 in (0.7 - 0.8 mm). See
Figure 4-4
.
Figure 4-4. Spark Plug
NOTE:
Replace spark plug if electrodes are
pitted, burned or porcelain is cracked. Use
ONLY recommended replacement plug. See
Specifications.
4. Install spark plug finger tight, and tighten
an additional 3/8 to 1/2 turn using spark
plug wrench.
Battery Replacement
NOTE:
The battery shipped with the generator
has been fully charged. A battery may lose
some charge when not in use for prolonged
periods of time. If battery is unable to crank
engine, use a 12V battery charger to charge
the battery.
See
Figure 4-5
.
1. Disconnect negative (-) battery terminal
FIRST (black wire).
2. Disconnect positive (+) battery terminal
SECOND (red wire).
Figure 4-5. Battery Connection
3. Install new battery (A). Install hold down
bracket (B), insert threaded rod (C) and
tighten with M6 nuts (D). See
Figure 4-6
.
Figure 4-6. Battery Connection
4. Connect positive (+) battery terminal (red
wire) FIRST. Slide rubber boot over con-
nection hardware.
5. Connect negative (-) battery terminal
(black wire) SECOND.
6. Slide rubber boot over connection hard-
ware.
• Always recycle batteries in accordance
with local laws and regulations. Contact
your local solid waste collection site or
recycling facility to obtain information on
local recycling processes. For more infor-
mation on battery recycling, visit the Battery
Council International website at: http://bat-
terycouncil.org/.
Inspect Muffler and Spark
Arrester
NOTE:
It is a violation of California Public
Resource Code, Section 4442, to use or oper-
ate the engine on any forest-covered, brush-
covered, or grass-covered land unless the
exhaust system is equipped with a spark
arrester, as defined in Section 4442, main-
tained in effective working order. Other states
or federal jurisdictions may have similar laws.
Contact original equipment manufacturer,
retailer, or dealer to obtain a spark arrester
designed for exhaust system installed on this
engine.
NOTE:
Use ONLY original equipment replace-
ment parts.
Inspect muffler for cracks, corrosion, or other
damage. Remove spark arrester, if equipped,
inspect for damage or carbon blockage.
Replace parts as required.
000211
(000130)
WARNING
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
002719
002720
A
B
C
D
WARNING
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death or serious injury.
(000228)
Summary of Contents for DF3500E Series
Page 22: ...20 Owner s Manual for Portable Generator Notes...
Page 23: ......
Page 49: ...23 Manual del propietario para generador port til Notas...
Page 50: ...Manual del propietario para generador port til 24...
Page 51: ......
Page 75: ...21 Owner s Manual for Portable Generator REMARQUE...