Owner’s Manual for Portable Generator
13
Changing Fuels
1. Make sure generator is turned OFF.
2. Unplug all electrical loads from the unit's
receptacles.
3. Place generator on a level surface.
4. If switching from LPG to gasoline, make
sure the LPG Tank valve is turned OFF
and disconnect LPG fuel tank from gener-
ator.
If switching from Gasoline to LPG, follow the
LPG connecting procedure in section
Liquid
Petroleum Gas (LPG)
.
5. Turn the Fuel Selection Dial to the desired
fuel.
6. Check fuel supply of the selected fuel.
7. Follow the
Starting Pull Start Engines
or
Starting Electric Start Engines
procedure
to start the generator.
Starting Pull Start Engines
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. Open the fuel shut-off valve (A). See
Fig-
ure 3-2
.
.
Figure 3-2.Fuel Shut-off Valve
4. Turn engine Start/On/Off switch (B) on the
control panel to On (manual start only).
See
Figure 3-3
.
5. Move engine choke knob (C) on control
panel outward to Full Choke position. See
Figure 3-3
.
Figure 3-3.Choke Position
6. Firmly grasp recoil handle and pull slowly
until increased resistance is felt. Pull rap-
idly up and away.
7. When engine starts, move choke knob to
1/2-choke position until engine runs
smoothly, then fully into Off position. If
engine falters, move choke back to 1/2-
choke position until engine runs smoothly,
then to Off position.
NOTE:
If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload the
generator. Also, do not overload individual
panel receptacles. These outlets are pro-
tected against overload with push-to-reset-
type circuit breakers. If amperage rating of
any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
Know Generator
Limits
carefully.
(000105)
DANGER
Explosion and Fire. Fuel and vapors are extremely
flammable and explosive. Add fuel in a well
ventilated area. Keep fire and spark away. Failure to
do so will result in death or serious injury.
(000199)
DANGER
Explosion and Fire. LP vapors are extremely flammable
and explosive. Do not use or store LP cylinder in a
building, garage, or enclosed area except as authorized
by NFPA 58 or B149.2 (Canada). Failure to do so will
result in death or serious injury.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
(000183)
WARNING
Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
002148
A
002149
C
C
B
B
DF3500E
DF7500E
Summary of Contents for DF3500E Series
Page 22: ...20 Owner s Manual for Portable Generator Notes...
Page 23: ......
Page 49: ...23 Manual del propietario para generador port til Notas...
Page 50: ...Manual del propietario para generador port til 24...
Page 51: ......
Page 75: ...21 Owner s Manual for Portable Generator REMARQUE...