DO NOT
run the pump without the water supply connect-
ed and turned on. Damage to the Waterblaster resulting from failure to
follow this instruction
WILL
void the warranty.
3. For your protection, wear protective safety glasses (not provided).
4. Move the Waterblaster
OUTSIDE
in a fully
VENTILATED
area.
5. Place the Waterblaster on a
FLAT
and level surface and close to the working
surface. Keep a minimum of
1.5 meters CLEARANCE
on all sides of the engine
including top. Face the engine exhaust outlet
AWAY
from dwellings.
6. Make sure the Throttle lever is
set to the
“FAST”
position (left).
7. Slide the Petrol Valve lever to
“ON”
position (right) to allow
the petrol to flow to the engine.
8. Slide the Choke Lever to
“START”
position (left).
9. Turn the Engine
ON/OFF
switch
clockwise to
ON
position.
10.Point nozzle to a safe direction
and squeeze the Spray Gun
trigger to allow for easier
engine start.
11.To start the engine, pull Starter cord slowly until resistance is felt, then pull
rapidly to avoid kick back. Repeat until engine starts to run. Release the trigger.
12.Slide Choke Lever to
“RUN”
(right) position..
OPERATING
Do not leave Waterblaster in bypass mode for more than three minutes at a
time. Water temperature inside the pressure pump will rise to a dangerous
level resulting in damage to the internal components of the pump. Failure to
follow this warning will void warranty.
DO NOT
run the pressure pump without the water supply connected and turned
on. Damage to the Waterblaster resulting from failure to follow this
instruction
WILL
void the warranty.
ALWAYS
wear approved safety glasses
when operating
waterblasters.
Spray can splash back or propel objects, including
incorrectly attached accessories.
21
ON/OFF SWITCH
PETROL VALVE
CHOKE
SPEED CONTROL
STARTER CORD
Summary of Contents for EGS0252