PREVENTATIVE MAINTENANCE
SEAT
LOCK
SEAT
FLUID LEVEL
SIGHT
GAUGE
HYDRAULIC
OIL FILTER
FLUID
PRESSURE
GAUGE
RESERVOIR
FILL CAP W/
BREATHER
AND DIP
STICK
FILTER
PRESSURE
GAUGE
Fig. 2: Hydraulic Fluid Reservoir location
Fig. 3: Hydraulic Fluid Gauges
HYDRAULIC SYSTEM
Hydraulic Fluid Reservoir
The hydraulic fl uid reservoir is located behind the right side
door under the operator seat. (See Fig. 1)
Note:
The reservoir fi ll cap has a built-in breather and dip
stick. Replace the cap every 100 hours of operation.
Note:
The hydraulic oil fi lter contains a replaceable element.
Replace the fi lter element every 100 hours of operation.
The reservoir has a sight gauge to quickly view if there is a
suffi cient amount hydraulic oil in the reservoir tank to run the
machine. Check daily and add hydraulic oil as needed.
When the machine is cool unscrew the fi ll cap and check the
fl uid level on the attached dip stick. The fl uid level should
be between the high and low markers. The cap should be
screwed down hand tight and unscrewed to get a proper oil
level reading. Add or remove hydraulic fl uid as needed.
CAUTION
DO NOT OVERFILL HYDRAULIC RESERVOIR TANK!
DO NOT USE TRANSMISSION FLUID!