background image

IMPORTANT SAFETY INSTRUCTIONS 

 
Operators must read and understand this manual before operating or 
maintaining this machine. 
Do not operate this machine in flammable or explosive areas. 

This machine is designed solely for scrubbing dirt and dust in an indoor environment. 

PowerBoss

 does not recommend using this machine in any other capacity. 

The following information below may cause a potential hazard to the operator and 
equipment. Read this manual carefully and be aware when these conditions can exist. 
Take necessary steps to locate all safety devices on the machine and train the 
personnel operating the machine. Report any machine damage or faulty operation 
immediately. 

Do not use machine if it is not in proper operating condition.

 

FOR SAFETY DURING OPERATION: 

Keep hands and feet clear of moving parts while machine is in operation. 
Make sure all safety devices are in place and operate properly. All covers, doors and 
latches must be closed and fastened before use. 
During operation, attention should be paid to other persons in the work area and 
especially if small children are present.

 

Electric motors and components can cause an explosion when operated near 
explosive materials or vapor. Do not operate this machine near flammable materials 
such as solvents, thinners, fuels, grain dust, etc.

 

 

Store or park this machine on a level surface only, with parking brake engaged. To 
prevent unauthorized use, machine should be stored or parked with the key removed.

 

This machine is designed for level operation only. 

Do not operate on ramps or 

inclines

This machine is not suitable for picking up hazardous dusts. 
Use caution when moving this machine into areas that are below freezing 
temperatures. Any water in the tanks or hoses can cause damage to the machine. 

FOR SAFETY WHEN SERVICING or MAINTAINING MACHINE: 

Stop on level surface. 
Disconnect the power to the machine by pulling the large red handle (Anderson Plug) 
located in the back of the machine, mid-right, when charging batteries or during 
installation or removal of brushes. 
Avoid moving parts. Do not wear loose jackets, shirts, or sleeves when working on 
machine. 
Avoid contact with battery acid. Battery acid can cause burns. When working on or 
around batteries, wear protective clothing and safety glasses. Remove metal jewelry. 
Do not lay tools or metal objects on top of batteries. 
Charging batteries generates explosive gasses. 

Do not charge batteries when open 

flames or sparks are present. Do not smoke. 

Make sure the charger is turned off 

before disconnecting it from the machine. 
Charge the batteries in a well-ventilated area with the battery cover removed 
completely. 
Do not clean machine with a pressure washer. 
Authorized personnel must perform repairs and maintenance. Use PowerBoss 
supplied replacement parts. 

SAVE THESE INSTRUCTIONS 

 

3

Summary of Contents for CP 2832

Page 1: ...WALK BEHIND SCRUBBER User Manual PHOENIX 30 34...

Page 2: ...ow Operate the machine with reasonable care Follow the manufacturers suggested maintenance instructions as provided in this booklet Use original PowerBoss supplied parts TECHNICAL SPECIFICATIONS Model...

Page 3: ...Store or park this machine on a level surface only with parking brake engaged To prevent unauthorized use machine should be stored or parked with the key removed This machine is designed for level op...

Page 4: ...age 13 for service and installation OPERATOR RESPONSIBILITY Read this manual carefully before operating this machine The operator is responsible in taking care of the daily maintenance and check ups o...

Page 5: ...SWITCH HOUR METER EMERGENCY BELLY BAR A B C D E F G H I A B H F D C E I G MACHINE COMPONENTS CONTROL CONSOLE ACCELERATION LEVER SPEED CONTROL KNOB DIRECTIONAL LEVER DIRECTIONAL INDICATOR KEY SWITCH EM...

Page 6: ...depressed it will override the directional switch and force the Phoenix to go forward Most useful if backed into a corner or object to prevent from pinching the operator Off aisle wand switch G On Of...

Page 7: ...s similar to Regular Scrub The machine will continue to operate the same was as if it was in Regular Scrub Mode only this mode applies more solution and brush pressure is increased This mode is used f...

Page 8: ...r a few seconds 5 TRANSPORT MODE When the machine is set in this mode none of the cleaning functions of the machine will operate This mode is only used to transport the machine from one location to an...

Page 9: ...oller Each main component is individually protected with an internal breaker built in the controller See fault code table and can be reset by turning the key switch off a few seconds and then on again...

Page 10: ...efficient agitation of cleaning solution to the floor and channeled to the rear of the machine The disc brushes are also easily removed and installed with the quick release clamp by using any of the t...

Page 11: ...ine Install brushes on the scrub deck this aids the installer in sliding the deck assembly into position Make sure the scrub deck is oriented correctly with the solution hose tee fitting towards the f...

Page 12: ...emove the two access doors one each end by removing the 3 nyloc nuts Install the brushes by sliding through the access opening Align the notches on the brush with the drive pins on the hub Push brush...

Page 13: ...ns Each blade configuration has two usable edges The rear blade however has four usable edges The squeegee is pre adjusted at the factory Adjustments may be required to get optimum performance for dif...

Page 14: ...Adjust the casters and retighten the wing jam nuts to lock the caster setting in place Pitch adjustment is necessary if the outer ends on the squeegee blade do not contact the floor and there is too...

Page 15: ...ge of motion and the solution hose to be inside the recovery hose The trigger controls the solution flow to the spray jet Squeezing the trigger opens an internal valve to dispense cleaning solution Th...

Page 16: ...evels should be checked before and after charging and maintained at the proper levels If low add distilled water until the metal plates are covered If the machine is not used for an extended period of...

Page 17: ...then required to stop scrubbing and empty the recovery tank To stop scrubbing select the Transport mode This will automatically stop the Solution Flow raise the Scrub deck and raise the Rear squeegee...

Page 18: ...Water Level Lubrication Grease Fittings chains etc Check Carbon Brushes Check Clean Tanks Hoses Inspect Scrub Housing Skirts Check Clean Rotate the Brushes Pads Inspect and Clean Solution Filter Chec...