Installation and operating manual
Page 39 of 95
(PVI-3.8/4.6-I-OUTD Rev.: 1.5)
3.5
CR2032 Lithium Battery Replacement
WARNING:
Before
carrying
out
any
operation,
follow
the
connection/disconnection procedure detailed in paragraph 3.4.1.
Inside AURORA, there is a CR2032 lithium battery. When the battery is at its end-of-
life, a message will be shown on the display indicating the battery state.
The battery can easily be seen once the front panel has been removed (see
Fig.
15
).
The component cannot be assembled vertically to its container, but it must be inserted
from the side (Side A), at an angle of around 30°. The component will rotate inside the
battery port until it seats in the right position.
Fig. 15 – Lithium battery replacement
WARNING: The battery must be replaced by qualified personnel only.
3.6
Replacement of the memory
WARNING:
Before
carrying
out
any
operation,
follow
the
connection/disconnection procedure detailed in paragraph 3.4.1.
All historical data relative to the system energy production are stored in this memory.
If the inverter must be replaced, the memory can simply be removed from the old unit,
and reinserted into the new one. By so doing, you can continue to save present and
future daily data on this memory, and avoid losing the data already stored in it. See
Fig. 16.