Installation and operating manual
Page 23 of 95
(PVI-3.8/4.6-I-OUTD Rev.: 1.5)
3.3.1
Wall mounting
Included in the shipping package is a kit containing 4 steel screws 6.3x70 (with 4 M6
washers) and 4 SX10 anchors, necessary for attaching the metal bracket to a concrete
wall. Screws and anchors can be inserted into the 3 holes on the metal bracket (Part.
B), and then into the hole on the bottom of the inverter.
WARNING: The bracket must be attached to the wall vertically, the side
with the hook (Part. C) must be facing upwards, while the side with the PEM
M6 (Part. G) must be facing downwards.
NOTE: If the device is to be mounted onto a concrete wall, holes must be
created of diameter 10mm and depth 75mm.
NOTE: When the device is installed on walls of materials other than
concrete, suitable screws and anchors should be used. Power-One
recommends always using stainless steel screws.
Attach the inverter to the hook (Part. C) present on the upper part of the bracket by
using the metal fin, fixed onto the upper part of the rear of the inverter. This metal fin
has a point (Part. D) in correspondence to the fixing hook of the wall-mounting
bracket (Part. C).
Once the upper part of the inverter has been attached, fix the lower part to the PEM
M6 present on the bracket, by using the special slot on the lower flange of the inverter
(Part. H).
Summary of Contents for Aurora PVI-3.8/4.6-I-OUTD
Page 96: ......