background image

13

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

Ref. 

No.

Qty

Description

USED ON

Part Numbers

1

1

Volute, Std

PF055400

Volute, PFSE51HT

PF071114

2

1

*

Impeller - 6.00” Dia. - Std 1.0HP, (* See Note 1)

PF084346

Impeller - 5.50” Dia. - Std .75HP, (* See Note 1)

PF084346TD

Impeller - 5.25” Dia. - Std .50HP, (* See Note 1)

PF084346TF

Impeller - 5.00” Dia. , (* See Note 1)

PF084346TH

Impeller - 4.50” Dia., (* See Note 1)

PF084346TM

Impeller - 4.00” Dia., (* See Note 1)

PF084346TR

3

1

O-ring

PF63PFU3101

4

1

V-Seal

PF068053

5

1

Shaft Seal - 5/8”

PF068988

6

1

Gasket

PF27344

7

2

Socket hd screw 1/4-20 x 1.25” Lg

8

1

Seal plate (for inboard seal)

PF026205

9

1

Square ring - NBR

STD

PF074498

Square ring - Silicon

HT

PF63S041352

10

1

Motor housing

PF105196

11

1

Retaining ring

PF85326

12

1

Terminal block, 1Ph

PF103584

Terminal block, 3Ph

PF103583

13

1

O-ring - NBR

STD

PF2-31051-224

O-ring - Silicon

HT

PF63PFS5103

14

1

Retaining ring

PF105197

15

1

Handle

PF103503

16

2

Hex hd screw, 5/16-18 x 1.00” Lg

17

2

Lockwasher, 5/16”

18

1

Pipe plug, 3/8 NPT

19

2

Hex hd capscrews, 3/8-16 x 1.25” Lg

20

4

Hex hd capscrews, 5/16-18 x 1.87” Lg

21

4

Lockwasher, 5/16

Parts List

For Repair Part Please supply: Model Number and MFG Date as shown on 

Name Plate, and Part Description and Part Number as shown on Parts List.

PFSE .05, .75, 1HP,  Std & High Temp   

 

 

 

 

 

Sewage Pumps

 =  Aquire standard hardware locally.

 = Overhaul Kit

 = Supplied as individual items

Model Number     

MFG Date

AMPS        

         VOLTAGE     

PHASE    

60 Hz        HP    

877-24 PUMPS

www.powerflopumps.com

   US

Typical NamePlate

(*) Note 1: Design change; Added item 40 nut on units 

dated after 11/2010. Must use nut ,item #40 with any 

replacement impellers shipped after 11/2010.

Summary of Contents for PFSE1044 Series

Page 1: ...SP 1 2021 INSTALLATION SERVICE PARTS MANUAL Series PFSE51 PFSE51A PFSE51HT PFSE52 PFSE594 PFSE544 0 5 HP 1750 RPM 60 Hz Standard High Temperature Series PFSE774 PFSE794 PFSE744 0 75 HP 1750 RPM 60 Hz...

Page 2: ...nnected Always wear eye protection when working on pumps Do not wear loose clothing that may become entangled in moving parts Pumps build up heat and pressure during operation Allow time for pumps to...

Page 3: ...cal Oil Filled Material Carbon Ceramic Buna N POWER CORD 15 Ft Cord with Plug on 115 Volt 1 2HP 230 Volt 1 Phase Fast Disconnect Design MOTOR Oil Filled Squirrel Cage Induction Class B Insulation SING...

Page 4: ...6 4 2 9 7 11 1 5 34 10 68 K 14 4 SOW PFSE544 0 5 460 3 60 1750 2 2 5 3 5 34 10 68 K 14 4 SOW PFSE774 0 75 200 230 1 60 1750 8 4 7 7 21 4 25 7 J 14 3 SOW PFSE794 0 75 200 230 3 60 1750 4 8 4 5 13 6 15...

Page 5: ...5 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PFSE 05 75 1HP Sewage Pumps...

Page 6: ...ions Performance MODEL HP VOLTS PH HZ RPM FULL LOAD AMPS LOCKED ROTOR AMPS WINDING RESISTANCE MAIN START NEMA START CODE CORD SIZE CORD TYPE PFSE51HT 0 5 115 1 60 1750 11 6 21 2 E 14 3 SOOW 8 00 Disch...

Page 7: ...o be installed or removed without requiring personnel to enter the station or resting on the basin floor Discharge Piping Discharge piping should be as short as possible and sized no smaller than the...

Page 8: ...e pump has been properly wired lowered into the basin sump or lift station check the system by lling with liquid and allowing the pump to operate through its pumping cycle The time needed to empty the...

Page 9: ...3 4HP 67 6 oz 1HP 74 4 oz BP Enerpar SE100 Conoco Pale Paraf n 22 Mobile D T E Oil Light Shell Canada Transformer 10 Texaco Diala Oil AX Disassembly Impeller andVolute 1 Disconnect power 2 Remove caps...

Page 10: ...nd seal parts into seal plate 8 until bearing seats into seal plate Insert retaining ring 11 into seal plate 8 Place stator over rotor lining up motor bolts with holes in seal plate 8 Insert motor bol...

Page 11: ...tor Lead Number Green Ground Green Black 1 White 2 Flag Terminal Capacitor Flag Terminal Capacitor Power Cable Motor Lead Number Green Ground Green 1 1 7 2 2 8 3 3 9 4 5 6 Together Power Cable Motor L...

Page 12: ...24PUMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 7 PFSE 05 7...

Page 13: ...Retaining ring PF85326 12 1 Terminal block 1Ph PF103584 Terminal block 3Ph PF103583 13 1 O ring NBR STD PF2 31051 224 O ring Silicon HT PF63PFS5103 14 1 Retaining ring PF105197 15 1 Handle PF103503 16...

Page 14: ...1 Bearing Supplied w Motor 26 1 Motor end bell Supplied w Motor 27 4 Motor screws Supplied w Motor 28 29 30 1 Motor Assy 0 5HP 115 volt 1Ph PF030369BS 0 5HP 75HP 230 volt 1Ph PF071325BS 0 5HP 75HP 23...

Page 15: ...ase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits and fluid temperature 13 Replace...

Page 16: ...been exposed to outside substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive...

Reviews: