background image

16

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

PFSE .05, .75 & 1HP 

 

 

 

 

 

 

 

 

Sewage Pumps

2 YEAR WARRANTY

Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, new pump product 
to be free from defects in material and workmanship under normal use and service, when properly used and 
maintained, for a period of 2 years from date of sale. The date of sale shall be determined by a dated sales receipt 
noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump 
if the date of the return is more than 2 years from the date of manufacturer. Product will be repaired, replaced 
or remanufactured at Manufacturer’s option. No allowance will be made for shipping charges, damages, labor 
or other charges that may occur due to product failure, repair or replacement. This warranty does not apply to 
and there shall be no warranty for any material or product that has been disassembled without prior approval 
of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not 
been  installed,  operated  or  maintained  in  accordance  with  Manufacturer’s  installation  instructions;  that  has 
been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, 
hydrocarbons,  hydrocarbon  derivatives  (oil,  gasoline,  solvents,  etc.),  or  other  abrasive  or  corrosive  substances, 
wash towels or feminine sanitary products, etc. in all pumping applications. The warranty set out in the paragraph 
above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other 
person to assume for us any other liability in connection with our products.

Contact  Manufacturer  at:  1-877-24PUMPS  or  www.powerflopumps.com,  Attention:  Customer  Service 
Department, to obtain any needed repair or replacement of part(s) or additional information pertaining 
to  our  warranty.  MANUFACTURER  EXPRESSLY  DISCLAIMS  LIABILITY  FOR  SPECIAL,  CONSEQUENTIAL  OR 
INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY 
OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION 
OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply 
to you. Some states do not allow the exclusion or limitation of incidental or con sequential damages, so the above 
limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have 
other rights which vary from state to state.

Summary of Contents for PFSE1044 Series

Page 1: ...SP 1 2021 INSTALLATION SERVICE PARTS MANUAL Series PFSE51 PFSE51A PFSE51HT PFSE52 PFSE594 PFSE544 0 5 HP 1750 RPM 60 Hz Standard High Temperature Series PFSE774 PFSE794 PFSE744 0 75 HP 1750 RPM 60 Hz...

Page 2: ...nnected Always wear eye protection when working on pumps Do not wear loose clothing that may become entangled in moving parts Pumps build up heat and pressure during operation Allow time for pumps to...

Page 3: ...cal Oil Filled Material Carbon Ceramic Buna N POWER CORD 15 Ft Cord with Plug on 115 Volt 1 2HP 230 Volt 1 Phase Fast Disconnect Design MOTOR Oil Filled Squirrel Cage Induction Class B Insulation SING...

Page 4: ...6 4 2 9 7 11 1 5 34 10 68 K 14 4 SOW PFSE544 0 5 460 3 60 1750 2 2 5 3 5 34 10 68 K 14 4 SOW PFSE774 0 75 200 230 1 60 1750 8 4 7 7 21 4 25 7 J 14 3 SOW PFSE794 0 75 200 230 3 60 1750 4 8 4 5 13 6 15...

Page 5: ...5 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PFSE 05 75 1HP Sewage Pumps...

Page 6: ...ions Performance MODEL HP VOLTS PH HZ RPM FULL LOAD AMPS LOCKED ROTOR AMPS WINDING RESISTANCE MAIN START NEMA START CODE CORD SIZE CORD TYPE PFSE51HT 0 5 115 1 60 1750 11 6 21 2 E 14 3 SOOW 8 00 Disch...

Page 7: ...o be installed or removed without requiring personnel to enter the station or resting on the basin floor Discharge Piping Discharge piping should be as short as possible and sized no smaller than the...

Page 8: ...e pump has been properly wired lowered into the basin sump or lift station check the system by lling with liquid and allowing the pump to operate through its pumping cycle The time needed to empty the...

Page 9: ...3 4HP 67 6 oz 1HP 74 4 oz BP Enerpar SE100 Conoco Pale Paraf n 22 Mobile D T E Oil Light Shell Canada Transformer 10 Texaco Diala Oil AX Disassembly Impeller andVolute 1 Disconnect power 2 Remove caps...

Page 10: ...nd seal parts into seal plate 8 until bearing seats into seal plate Insert retaining ring 11 into seal plate 8 Place stator over rotor lining up motor bolts with holes in seal plate 8 Insert motor bol...

Page 11: ...tor Lead Number Green Ground Green Black 1 White 2 Flag Terminal Capacitor Flag Terminal Capacitor Power Cable Motor Lead Number Green Ground Green 1 1 7 2 2 8 3 3 9 4 5 6 Together Power Cable Motor L...

Page 12: ...24PUMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 7 PFSE 05 7...

Page 13: ...Retaining ring PF85326 12 1 Terminal block 1Ph PF103584 Terminal block 3Ph PF103583 13 1 O ring NBR STD PF2 31051 224 O ring Silicon HT PF63PFS5103 14 1 Retaining ring PF105197 15 1 Handle PF103503 16...

Page 14: ...1 Bearing Supplied w Motor 26 1 Motor end bell Supplied w Motor 27 4 Motor screws Supplied w Motor 28 29 30 1 Motor Assy 0 5HP 115 volt 1Ph PF030369BS 0 5HP 75HP 230 volt 1Ph PF071325BS 0 5HP 75HP 23...

Page 15: ...ase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits and fluid temperature 13 Replace...

Page 16: ...been exposed to outside substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive...

Reviews: