4
Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com
Dimensions
MODEL
HP
VOLTS
PH
HZ
RPM
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
WINDING RESISTANCE
MAIN -- START
NEMA
Start
Code
CORD
SIZE
CORD
TYPE
PFSE51
0.5
115
1
60
1750
11.6
21.2
1.35 -- 11.10
E
14/3
SJTOW
PFSE51A
0.5
115
1
60
1750
11.6
21.2
1.35 -- 11.10
E
14/3
SJTOW
PFSE52
0.5
230
1
60
1750
5.9
14.9
B
14/3
SOW
PFSE594
0.5
200-230
3
60
1750
4.6/4.2
9.7/11.1
5.34 -- 10.68
K
14/4
SOW
PFSE544
0.5
460
3
60
1750
2.2
5.3
5.34 -- 10.68
K
14/4
SOW
PFSE774
0.75 200-230
1
60
1750
8.4/7.7
21.4/25.7
J
14/3
SOW
PFSE794
0.75 200-230
3
60
1750
4.8/4.5
13.6/15.3
5.40 -- 10.72
K
14/4
SOW
PFSE744
0.75
460
3
60
1750
2.0
7.7
5.63 -- 11.14
K
14/4
SOW
PFSE1074
1.0
200-230
1
60
1750 13.6/12.4 21.4/25.7
2.2 -- 7.6
G
14/3
SOW
PFSE1094
1.0
200-230
3
60
1750
9.0/8.2
13.7/15.4
2.91 -- 5.78
G
14/4
SOW
PFSE1044
1.0
460
3
60
1750
3.8
7.7
2.97 -- 5.94
H
14/4
SOW
Mechanical Switch on “A” cord is 16/2, SJOW, Piggy-Back Plug.
PFSE .05, .75 & 1HP
Sewage Pumps
Float Shown is for PFSE51A