11
Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com
Press the terminal block (12) into bore
of motor housing (10) aligning timing
mark with hole in terminal block, so it
seats completely below the retaining
ring groove. Place retaining ring (14) into
groove into motor housing. Compress
cable plug with flange on cable assembly
(22) by tightening capscrews (16) with
lockwashers (17) into motor housing and
torquing to 132 in-lbs.
Power Cable
Motor Lead Number
Green (Ground) Green
Black
1
White
2
Flag Terminal
Capacitor
Flag Terminal
Capacitor
Power Cable
Motor Lead Number
Green (Ground) Green
1
1 & 7
2
2 & 8
3
3 & 9
4, 5 & 6 Together
Power Cable
Motor Lead Number
Green (Ground) Green
1
1
2
2
3
3
4 & 7 Together
5 & 8 Together
6 & 9 Together
Power Cable
Motor Lead Number
Green (Ground) Green
1
1
2
2
3
3
Figure 6 - 115/230 Volt AC, 1Ph
Models: PFSE51, PFSE52, PFSE774,
PFSE1074
Service
Figure 4
Figure 6 - 200/240 Volt AC, 3Ph
Models: PFSE594, PFSE794, PFSE1094
Figure 6 - 480 Volt AC, 3Ph
Models: PFSE544, PFSE744, PFSE1044
PFSE .05, .75 & 1HP
Sewage Pumps
Figure 5
Figure 6 - 575 Volt AC, 3Ph
Models: PFSE554, PFSE754, PFSE1054