Power Test (status 1)
1. Environmental conditions
– visual check
Verify that the equipment environment complies with the specifications. Verify that the humidity is
adequate.
2. Enclosure state
– visual check
Check the enclosure is in good general state and no traces of corrosion or impacts are present. Check
the posts anchoring.
3. Remote Access - connection to the App
Verify that the equipment can be accessed remotely. If it is required, verify the connection with the App.
4. Charge connector operation
– visual and manual check
Check the condition of the hoses and charging connectors, check that they are in good condition and
have no impact, cut or other marks.
5. Charge test (optional)
It is recommended to perform a complete charge on an electric vehicle to verify that it is finished
correctly and the communications are working fine.
If the charge test is performed,
it is the customer´s responsibility
to ensure the presence of an
electric vehicle to perform the charging procedure with each type of connector.
If the charge test is performed,
the costs derived from it must be assumed by the customer.
6. Operation of the differential switch
– visual and manual
check
Check the correct operation of the differential switch using the test button enabled for this purpose on
the differential itself. Open the unit without voltage, then energize it without any load, carry out the test
and finally close the door. May wear the PPE needed for this task.