Page 25
The gearbox is factory filled with oil and should be sufficient for the life of the unit. It is
important that the units are inspected to ensure no leaks have developed. Check C-
face connections for any looseness.
The cable clamps are to be inspected on the drum, ensuring each bolt is tight.
Make certain the basic operation of the
Mat Mover
®
functions properly
,
with the limit
switches shutting off correctly.
The upper limit actuator bars are to be lightly greased in the telescopic portion.
For units with cable tie-off at frame, check 3/4” bolt for tightness, and visually inspect
welds and connection of cable at the frame (end plate and support plate) for fatigue.
Contact factory if there is any question of structural integrity.
Replace covers, ensuring all screws are tight, to eliminate any vibration noise.
6. SLING
The mat sling is to be checked for signs of tearing or loosening at the seams. Check
stitching on all straps. The sling may be cleaned with a mild solution of soap cleaner
and water, or power foam sold by Rigmar Industries of Elk Grove Village, Illinois (1
-800-323-0779).
7. CONTRACT MAINTENANCE ALTERNATE
In many facilities, it is possible that the maintenance personnel either do not have the
ability or the scaffold to work at the heights required to perform the inspection and
maintenance program outlined in this manual. Should your maintenance program be
so limited that this program cannot be properly performed, it is highly recommended
that a contract-type inspection/maintenance service program be initiated with a
qualified and trained establishment in this type of equipment.
Summary of Contents for 91101-100
Page 4: ......
Page 18: ...Page 14 FIGURE J POWER SOURCE ...
Page 19: ...Page 15 FIGURE K BEFORE ...