background image

MAINTENANCE and OPERATING CHECKS 

 

 

 

 

It is essential to switch off the electric power before checking or maintenance operations, making sure that it can not 
inadvertently be reconnected

Don

t use the mixer if the cable is damaged, even if with small cuts of the outer sheath! 

 

 

 

 

MONTHLY CONTROLS 

Carefully  check  the  condition  of  the  cables  and  cable  glands.  Ensure  that  the  end  of  cable  is  protected  and  not 
submerged in the liquid, to avoid infiltration. 
Check that the external parts (shackles, chains, guide pipes) are intact, and that the screws and nuts are tight. 
Check  that  the  noise  level  of  the  bearings  meets  the  optimal  conditions  of  the  first  start-up.  Verify  that  the  motor 
insulation is above 

1 MΩ.

 

Check that the wear of the propeller does not compromise the performance of the machine. 

If the propeller is worn, it 

could have cutting edges and blades

: pay attention and use special work gloves. 

Check the oil in the sealed chamber for traces of liquid or emulsions. 

 

OIL CHANGE PROCEDURE 

-

 

unscrew the oil cap and replace always the o-ring on it 

-

 

drain the oil into a container to check it 

-

 

fill up new oil with viscosity 10cst (SAE 10W), recommended quantity: 0,25 l; 

-

 

reassemble in reverse order 

If  the  mechanical  seal  has  failed,  the  oil  chamber  may  be  under  pressure:  to  avoid 
splashes, hold a cloth on the oil cap and unscrew carefully. Do not dispose of used oil in 
the environment. 

 

Some advised types of oil

AGIP OTE 55 EP 

BP ENERGOL GS 68 

CASTROL HY SPIN VG 46 

IP HIDRUS 68 

ESSO TERESSO 68 

ESSO ENERGOL CS 125 

SHELL TELLUS OIL T 68 

 

 
 
 

IMPROPER OPERATION 

 

 

Any intervention must be carried out by qualified personnel!

 

 

 

 

PROBLEMS 

POSSIBLE CAUSES 

ADVICE 

THE MIXER 

DOES NOT START 

the control device indicates a fault 

check that the pump is cooled by the liquid and 
that  the  propeller  rotates  freely,  check  that  the 
thermal protection is inserted correctly. 
check that thermal sensors works 

there is no voltage in the system 

check  that  the  main  switch  is  activated,  all  the 
phases  of  the  power  cable  are  under  load,  the 
motor  cable  is  not  interrupted,  the  fuses  have 
continuity and are tightened 

other problems 

contact an authorized workshop 

THE MIXER IS BLOCKED 

the pump is overloaded 

check  that  the  density  of  the  liquid  is  not 
excessive;  disconnect  the  power  supply  and 
check that the impeller rotates without difficulty 

the current limiter has too low a regulation 

adjust the current limiter 

the motor protection switch is damaged 

replace the motor protection switch 

not all system phases are in voltage 

check the motor fuses or contact an electrician 

other problems 

contact an authorized workshop 

THE MIXER WORKS IN 

ANOMALOUS WAY 

the flow generated is not sufficient 

the propeller is worn and must be replaced 

the mixer vibrates or is noisy 

the  propeller  is  damaged  or  unbalanced,  the 
bearings are worn out 

the mixer will wear out abnormally 

the  liquid  contains  solid  abrasives  or  is 
chemically too aggressive for material of mixer 

other problems 

contact an authorized workshop 

 
 
 
 
 
 
 
 
 
 

- 7 - 

Summary of Contents for ECOMIX E0 Series

Page 1: ...AAAAAAAA AAAAAAAA IT MANUALE D USO E MANUTENZIONE Pag 02 EN USE AND MAINTENANCE MANUAL Pag 05 FR NOTICE D INSTRUCTIONS Pag 08 ES MANUAL DE USO Y MANTENIMIENTO Pag 11 01 09 2019 E0 E1 AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA UNI EN ISO 9001 2015 ...

Page 2: ...na o sue parti ausiliarie Se nel periodo di garanzia presenta un non corretto funzionamento il miscelatore deve essere reso al costruttore o ad un punto di assistenza autorizzato Per qualunque problema o applicazione speciale o per ogni eventuale ulteriore informazione non presente nel manuale invitiamo a contattare i ns uffici tecnici Alla ricezione della merce controllare che i dati indicati sul...

Page 3: ...nfigurazioni di installazione con tubo sono molteplici In configurazione T1 il tubo è fissato ad una staffa direttamente poggiata sulla soletta della vasca che dovrà quindi essere aperta La configurazione T2 prevede il fissaggio di una mensola a bordo vasca di modo che la staffa vi si possa installare sporgendo in parte dalla soletta la vasca sarà da ritenersi ancora aperta La configurazione T3 è ...

Page 4: ...cuni tipi di olii consigliati AGIP OTE 55 EP BP ENERGOL GS 68 CASTROL HY SPIN VG 46 IP HIDRUS 68 ESSO TERESSO 68 ESSO ENERGOL CS 125 SHELL TELLUS OIL T 68 FUNZIONAMENTO IRREGOLARE Qualunque intervento deve essere eseguito da personale qualificato INCONVENIENTI POSSIBILI CAUSE CONSIGLI IL MISCELATORE NON PARTE l apparecchio di comando indica guasto controllare che il motore sia raffreddato dal flui...

Page 5: ... of disassembly or tampering of the machine or its auxiliary parts If during the warranty there is an incorrect operation the mixer must be returned to the manufacturer or to an authorized service point For problems special application or any additional information not present in the manual please contact our technical offices Upon receiving the goods check that data indicated on the identificatio...

Page 6: ...stallation configurations with tube are multiple In T1 configuration the pipe is fixed to a bracket directly resting on the slab of the tank which must therefore be an open tank The T2 configuration foresees the fixing of a shelf on the edge of the tub so that the bracket can be installed partially protruding from the slab also in this case the tub will be considered open The T3 configuration is s...

Page 7: ...sed types of oil AGIP OTE 55 EP BP ENERGOL GS 68 CASTROL HY SPIN VG 46 IP HIDRUS 68 ESSO TERESSO 68 ESSO ENERGOL CS 125 SHELL TELLUS OIL T 68 IMPROPER OPERATION Any intervention must be carried out by qualified personnel PROBLEMS POSSIBLE CAUSES ADVICE THE MIXER DOES NOT START the control device indicates a fault check that the pump is cooled by the liquid and that the propeller rotates freely che...

Page 8: ...s de démontage ou manipulation de la machine ou de ses pièces auxiliaires Si pendant la garantie le fonctionnement est incorrect le agitateur électrique doit être renvoyée au fabricant ou à un point de service agréé Pour application spéciale problème ou pour information non présente dans le manuel contacter notre bureaux techniques A la rèception des merchandises vérifiez que les caractèristiques ...

Page 9: ...u moyen d un tube en porte à faux de 1 1 2 Les configurations d installation avec tube sont multiples En configuration T1 le tuyau est fixé à un support reposant directement sur la dalle du réservoir qui doit donc être ouvert La configuration T2 prévoit la fixation d une étagère sur le bord de sorte que le support puisse être installé partiellement en saillie de la dalle le réservoir sera considér...

Page 10: ...TROL HY SPIN VG 46 IP HIDRUS 68 ESSO TERESSO 68 ESSO ENERGOL CS 125 SHELL TELLUS OIL T 68 FONCTIONNEMENT IRRÉGULIER Toute intervention doit être effectuée par du personnel qualifié PROBLEMES CAUSES POSSIBLES REMEDES LE MÉLANGEUR PAS DÉMARRER le dispositif de contrôle indique un défaut vérifier que le moteur refroidit et que l hélice tourne librement vérifier que la protection thermique est correct...

Page 11: ...anipulación de la máquina o sus piezas auxiliares Si durante la garantía hay una operación incorrecta la mezcladora debe devolverse al fabricante o a un punto de servicio autorizado Para cualquier problema o aplicación especial o cualquier información adicional que no esté presente en el manual comuníquese con nuestras oficinas técnicas Al recibir las mercancías compruebe que los datos indicados e...

Page 12: ...n con tubería son múltiples En la configuración T1 la tubería se fija a un soporte que descansa directamente sobre la losa del tanque que por lo tanto debe abrirse La configuración T2 prevé la fijación de un estante en el borde de la piscina de modo que el soporte pueda instalarse sobresaliendo en parte de la losa La bañera aún se considerará abierta La configuración T3 es similar pero el soporte ...

Page 13: ...Non disperdere l olio usato in ambiente Tipos aceites recomendados AGIP OTE 55 EP BP ENERGOL GS 68 CASTROL HY SPIN VG 46 IP HIDRUS 68 ESSO TERESSO 68 ESSO ENERGOL CS 125 SHELL TELLUS OIL T 68 OPERACION IRREGULAR Cualquier intervención debe ser realizada por personal cualificado PROBLEMAS POSIBLES CAUSAS CONSEJOS EL MEZCLADOR NO PARTE la unidad de control indica fallo compruebe que el líquido enfrí...

Page 14: ...MAS ELÉCTRICOS n 1 cavo n 4 conduttori Fig 1 connessione Y Fig 2 connessione Δ n 1 cable n 4 conductors Fig 1 Y connection Fig 2 Δ connection n 1 câble n 4 conducteurs Fig 1 connexion Y Fig 2 connexion Δ n 1 cable n 4 conductores Fig 1 conexiòn Y Fig 2 conexiòn Δ 14 ...

Page 15: ...ug Bouchon d huile Tapón de aceite 12 Lanterna allogg Tenute Seal casing cover Couvercle garniture mec Tapa de la carcasa del sello 13 Elica Propeller Hélice Hélice 14 Dado blocca elica Nut lock propeller Hélice à écrou Tuerca de bloqueo de hélice 15 Cuscinetto superiore Upper bearing Roulement superior Rodamiento superior 16 Albero con rotore Shaft with rotor Arbre avec rotor Árbol con rotor 17 C...

Page 16: ...9 2006 CM MATERIALE 4 3 0 VERSIONE VERSION P CATENA O FUNE DI SOLLEVAMENTO LIFTING CHAIN OR ROPE SERIE MACCHINA SUPPORTO INFERIORE FONDO VASCA LOWER SUPPORT 3 2 5 QUESTO DISEGNO E VINCOLATO A NORMA DI LEGGE Ø 11 5 Installation with pile guide 40x40 5 CODICE GREZZO 1 400 Min 1 ECO MIX E0 E1 SUPPORTO FISSO BORDO VASCA UPPER BRACKET 1 5 0 Installazione con guida per palo 40x40 POS DATA DESCRIZIONE DI...

Page 17: ...on slab in open tank 1 L max 1700 mm 300620 1 MENSOLA SHELF 250 T3 Fissaggio con staffa e mensola a parete sotto soletta 1 8 0 CODICE LAVORATO 1 Ø 13 5 2 0 4 RICAVATO DA VERSIONE VERSION T 2 0 0 T3 Fixing through flask and upper bracket under slab Ø 13 5 min 400 mm 1 5 0 T2 Fissaggio Bordo vasca con staffa e mensola POMPE ROTOMEC 250 300621 POS DATA DESCRIZIONE DISEGNATO CONTROLL MODIFICATO 2 3 0 ...

Page 18: ...NOTE ...

Page 19: ...NOTE ...

Page 20: ...NFORMITÉ POMPE ROTOMEC s r l situé via Ponchielli 1 20063 CERNUSCO SUL NAVIGLIO MI déclare sous sa seule responsabilité que le produit est conforme aux dispositions de la Directives 2006 42 CE 2014 030 CE 2014 035 CE et normes harmonisées DECLARACION DE CONFORMIDAD POMPE ROTOMEC s r l ubicado en via Ponchielli 1 20063 CERNUSCO SUL NAVIGLIO MI declara bajo su exclusiva y exclusiva responsabilidad q...

Reviews: