Integrator’s Reference Manual for the VSX Series
4 - 106
gatewayprefix
Sets or gets the gateway prefixes for the corresponding speeds.
Syntax
gatewayprefix get “valid speed”
gatewayprefix set “valid speed” [“value”]
Feedback Examples
•
gatewayprefix set 168 90
(returned from
gatewayprefix set 168 90
)
•
gatewayprefix 168 90
(returned from
gatewayprefix get
168)
Comments
Some gateways require a number to be prepended (prefix) to the gateway
number. The prefix identifies which gateway is used to dial a call at a
particular data rate.
User interface screen location:
System > Admin Settings > Network > IP >
H.323 Settings
(page 4)
: Prefix
Parameter
Description
get
When followed by the
“valid speed”
parameter,
returns the current value for this speed.
“valid speed”
Valid speeds are: 56, 64, 2x56, 112, 2x64, 128, 168,
192, 224, 256, 280, 320, 336, 384, 392, 7x64, 8x56,
504, 512, 560, 576, 616, 640, 672, 704, 728, 768, 784,
832, 840, 16x56, 14x64, 952, 960, 1008, 1024, 1064,
1088, 1120, 1152, 1176, 1216, 1232, 1280, 1288,
24x56, 21x64, 1400, 1408, 1456, 1472, 1512, 1536,
1568, 1600, 1624, 1664, 1680, 1728, 1736, 32x56,
28x64, 1848, 1856, 1904, and 1920 kbps.
set
Sets the gateway prefix when followed by the
“value”
parameter. To erase the current setting, omit
“value”
.
“value”
Prefix (code) used for a particular call speed. Consult
your gateway instruction manual to determine which
codes are appropriate.
Summary of Contents for VSX 7000s Series
Page 169: ...System Commands 4 93 exit Ends the API command session Syntax exit ...
Page 390: ...Integrator s Reference Manual for the VSX Series A 14 ...
Page 400: ...Integrator s Reference Manual for the VSX Series C 2 ...
Page 406: ...Integrator s Reference Manual for the VSX Series E 4 ...
Page 410: ...Integrator s Reference Manual for the VSX Series F 4 ...