In the 

Fast Configuration

 

Wizard

 - 

SIP 

dialog box, set the following: 

13

Click the 

Next

 button.

14

Enter the required 

Security

 information in the dialog box. 

Field

Description

SIP Server

Select:

Specify 

– to manually configure SIP servers.

Off

 – if SIP servers are not present in the network.

SIP Server IP 
Address

Enter either the IP address of the preferred SIP server 
or its host name (if a DNS server is used).

Transport Type

Select the protocol that is used for signaling between 
the MCU and the SIP Server or the endpoints 
according to the protocol supported by the SIP Server:

UDP –

 Select this option to use UDP for signaling.

TCP –

 Select this option to use TCP for signaling.

TLS –

 Select this option to use the secured 

communication where the 

Signaling Host

 listens on-

secured port 5061 only. The supported security 
protocols are: TLS 1.0, SSL 2.0 and SSL 3.0.

Field

Description

SIP 
Authentication

Click this check box to enable authentication with the SIP 
server. 
Select this check box only if the authentication is enabled 
on the SIP proxy.

User 
Name

Enter the user name the RMX will use to 
authenticate itself with the SIP proxy. This 
name must be defined in the SIP proxy.

These 
fields can 
contain up 
to 
20 ASCII 
characters

Password

Enter the password the RMX will use to 
authenticate itself with the SIP proxy. This 
password must be defined in the SIP proxy.

Summary of Contents for RealPresence 4000

Page 1: ...In multiple rack installations the racks should be coupled together Use a regulating uninterruptable power supply UPS to protect the RMX from power surges and voltage spikes and to keep it operating i...

Page 2: ...nents match the packing slip 2 Unlock and lift the RMX top cover Make sure that the Installation Accessories kit contains the power cables and a USB Key and that the Rack Installation Accessories kit...

Page 3: ...window opens In Windows XP a The Polycom Documentation option is automatically selected Click OK In Windows 7 a Select Open Folder to view files using Windows Explorer b Double click the index hta fi...

Page 4: ...4000 Connect the following cables to the RMX 4000 rear panel For AC Power Supply connections Insert a power cable in each of the three AC Power Entry Modules PEM s For DC Power connections see the Har...

Page 5: ...PWR STATUS LEDs turn ON System power up sequence may take approximately 10 minutes During this time the parameters in the lan cfg file are uploaded from the USB key to the RMX s memory and applied dur...

Page 6: ...Client application on the workstation by entering in the browser s address line the IP Address of the control unit as defined in the USB key in the format http Control Unit IP Address and pressing Ent...

Page 7: ...r setting the Network Service in the Fast Configuration Wizard If Secured Communication is required on the RMX complete the Fast Configuration Wizard Login install the Certificate and then enable the...

Page 8: ...on MCU Host Name Enter the name of the MCU on the network Default name is RMX DNS Select Off if DNS servers are not used in the network Specify to enter the IP addresses of the DNS servers Note The IP...

Page 9: ...string with which the MCU registers itself with the gatekeeper The gatekeeper uses this string to identify the MCU when forwarding calls to it H 323 endpoints use this number as the first part of thei...

Page 10: ...UDP Select this option to use UDP for signaling TCP Select this option to use TCP for signaling TLS Select this option to use the secured communication where the Signaling Host listens on secured port...

Page 11: ...he authentication is enabled on the gatekeeper to enable the Collaboration Server to register with the gatekeeper Leave this check box cleared if the authentication option is disabled on the gatekeepe...

Page 12: ...nicode encoding Span Type Select the type of spans ISDN PSTN lines that are connected to the RMX Select either T1 or E1 Default T1 Note Only one Span Type E1 or T1 is supported on the RMX Service Type...

Page 13: ...equires to dial out Leave this field blank if a dial out prefix is not required The field can contain be empty blank or a numeric value between 0 and 9999 Default Blank Field Description Framing Selec...

Page 14: ...Save Continue After clicking Save Continue you cannot use the Back button to return to previous configuration dialog boxes The ISDN PSTN Network Service is created and confirmed 28 Click OK to contin...

Page 15: ...Time settings Option 1 Manually setting the RMX time Using the arrows modify the GMT Time and the GMT Offset to set the RMX time GMT Offset Displays the time zone difference between Greenwich and the...

Page 16: ...rd again to confirm its accuracy Flag Value Conference ID Length MCU The number of digits of the Conference ID that will be assigned by the MCU Range 2 16 Default 5 Note Selecting 2 digits limits the...

Page 17: ...ator showing the time remaining until the system start up is complete When the default RMX User is replaced the RMX Time is set and if there are no System Errors the green RDY LED on the CNTL unit on...

Page 18: ...e default conferencing entities are set to CP conferencing at a line rate of 384 kbps Auto Layout Polycom Skin and a duration of one hour The default Entry Queue EQ is set to Ad Hoc conferencing which...

Page 19: ...om IDs 1001 1002 1003 and 1004 H 323 Participants H 323 participants dial MCU Prefix in Gatekeeper Conference or Entry Queue ID Name For example if the MCU prefix in gatekeeper is 925 you can dial in...

Page 20: ...5 the ISDN PSTN participant dials this number with the appropriate area code for example 678 and country code 001 Conference Control Using DTMF Codes Operation DTMF String Individual Help 0 Conference...

Reviews: