![PMD Atlas Compact Complete Technical Reference Download Page 38](http://html1.mh-extra.com/html/pmd/atlas-compact/atlas-compact_complete-technical-reference_1569420038.webp)
Electrical Specifications
38
Atlas
®
Digital Amplifier Complete Technical Reference
3
For more information on Atlas overtemperature safety functions see
4.8.2, "Overtemperature Fault."
For more information on Atlas overvoltage and undervoltage safety functions see
For more information on Atlas Current Foldback safety functions see
Current Foldback
Continuous Current Limit,
Default:
2.12 A
Default:
7.07 A
Default:
14.1 A
Brushless DC Motor
Low Limit: 0.0 A
Low Limit: 0.0 A
Low Limit:
0.0 A
High Limit: 2.12 A
High Limit: 7.07 A
High Limit:
14.1 A
Continuous Current Limit, DC Default:
1.50 A
Default:
7.00 A
Default:
14.0 A
Brush Motor
Low Limit: 0.0 A
Low Limit: 0.0 A
Low Limit:
0.0 A
High Limit: 1.50 A
High Limit: 7.00 A
High Limit:
14.0 A
Continuous Current Limit, Step Default:
2.12 A
Default:
6.36 A
Default:
12.7 A
Motor
Low Limit: 0.0 A
Low Limit: 0.0 A
Low Limit:
0.0 A
High Limit: 2.12 A
High Limit: 6.36 A
High Limit:
12.7 A
Energy Limit, Brushless DC
Default:
2.95 A
2
sec
Default:
31.9 A
2
sec
Default:
127.5 A
2
sec
Motor
Low Limit: 0.0 A
2
sec
Low Limit: 0.0 A
2
sec
Low Limit:
0.0 A
2
sec
High Limit: 2.95 A
2
sec
High Limit: 31.9 A
2
sec
High Limit:
127.5A
2
sec
Energy Limit, DC Brush Motor
Default:
3.63 A
2
sec
Default:
32.2 A
2
sec
Default:
128.7 A
2
sec
Low Limit: 0.0 A
2
sec
Low Limit: 0.0 A
2
sec
Low Limit:
0.0 A
2
sec
High Limit: 3.63 A
2
sec
High Limit: 32.2 A
2
sec
High Limit:
128.7 A
2
sec
Energy Limit, Step Motor
Default:
2.95 A
2
sec
Default:
34.7 A
2
sec
Default:
138.9 A
2
sec
Low Limit: 0.0 A
2
sec
Low Limit: 0.0 A
2
sec
Low Limit:
0.0 A
2
sec
High Limit: 2.95 A
2
sec
High Limit: 34.7 A
2
sec
High Limit:
138.9 A
2
sec
Quantity
All Low
Power Atlas
All Medium
Power Atlas
All High
Power Atlas