PM MPC-5V100 Operation Manual Download Page 9

 

 

 

  4.Mute 

  5.Setting 

  6.Up   

  7.Down 

    Please do not change the settings during normal using.   

  Long  press  the  power  key  will  switch  off  the  refrigerator.  Long  press  the  power  button  again,  the 

refrigerator will work again.   

  Long press the keypad lock key (combination of keys) can lock the keypad. The keyboard lock LED are 

lit, all the keys are locked. Then long press the keypad lock again can be unlocked.   

 

Press “Mute” to stop buzzing if necessary, but the alarm indicator and code still display until the alarm 

disappear.   

  For  special  using,  please  contact  our  authorized  service  engineer  before  adjust  the  settings.  Wrong 

operation may cause abnormal working of the device, such as bad temperature uniformity and abnormal 

high/low temp alarm.   

  Notes:  the  general  high  and  low  temperature  alarm  values  are  within  the  set  temperature  range  of 

2~10 

 

3.2.2 Parameter settings   

When power on the medical refrigerator, the display screen displays internal temperature value. To change 

setting temperature, for example, the original set temperature is 2

  which now has to be adjusted to 5

please operate according to the following steps:

 

Serial No. 

Keys Operation 

Display 

 

Displays the inside temperature 

Press the key Set 

  for 3 seconds 

Displays the initial set data is 2

  and twinkles 

Press the key Up-regulation 

 

Figure increases 

Press the key 

Down-regulation 

 

Figure decreases 

 

Figure is 5

 

Press the key Set 

  for 3 seconds 

Saves  the  user  settings  and  displays  the  inside 
temperature 

 

Summary of Contents for MPC-5V100

Page 1: ...ON MANUAL Pharmacy Refrigerator MPC 5V100 VERSION 2020 10 MPC 5V100 The image shown here is indicative only If there is inconsistency between the image and the actual product the actual product shall...

Page 2: ...s goggles etc 2 Always adopt good health habits and operate strictly according to the product instruction 3 Everyone is obliged to be in charge of one own safety 4 Not Allowed direct contact with pati...

Page 3: ...perature The medical refrigerator realizes refrigeration through the heat dissipation of the back surface condenser In order to ensure normal operation and ventilation and heat dissipation the back an...

Page 4: ...3 2 1 Key function 7 3 2 2 Parameter settings 8 3 2 3 Error display 9 IV Routine Maintenance 10 4 1 Clean of incubator 10 4 2 Defrost 10 4 3 Care and maintenance 10 V Clearing of Fault and Maintenanc...

Page 5: ...oduct Diagram Structural diagram Due to the improvement and various models of products the actual product may be different from the diagram please in kind prevail Fan Shelf Glass door Door Lock Contro...

Page 6: ...mber Dismantle all package components including protection foam in the refrigerator body Please check accessories and data according to the packing list Please clean the product before use The product...

Page 7: ...ulator to be used cooperatively When the medical refrigerator is used the power supply is required to be equipped with a lower voltage air circuit breaker and a leakage protection device It is necessa...

Page 8: ...ed to put the goods to be stored in the refrigerator after the inside temperature falls to the operating temperature If there are too much goods to be stored it is advised to store separately for thre...

Page 9: ...mal working of the device such as bad temperature uniformity and abnormal high low temp alarm Notes the general high and low temperature alarm values are within the set temperature range of 2 10 3 2 2...

Page 10: ...emperature sensor goes wrong you should cut off the power and first check whether the connecting wire of the sensor is loose Please contact professional after sales service or distributor of us for pr...

Page 11: ...ged thereby causing faults During the rainy season vapors may be easily condensed on the surface of the glass door of the refrigerator In serious condition water may drip Please use dry cloth to wipe...

Page 12: ...cket is plugged or loosened If the power fuse is disconnected If the supply voltage is too low or too high Compressor breaks down If the temperature setting is right Temperature goes on decreasing aft...

Page 13: ...Main technical parameters 6 2 Electrical schematic diagram VII Packing list Model Temp Volume Power supply Refrigerant Dimension MPC 5V100 2 8 100L 220V 50Hz R600a 505 510 875 Model Operation instruc...

Reviews: