Safety Instruction: 

  Please read the handbook carefully when using the machine for the first time. 

  The medical refrigerator can only be operated by trained and authorized personnel. 

  The maintenance of the equipment can only be accomplished by professional service team 

  If operator runs into conditions not mentioned in the instruction, please contact  us for inquiring correct 

processing method. 

  Please use accessories provided by our company. if user uses other accessories, our not take charge of 

generated  negative  effects.  however,  the  user  can  apply  to  us  to  test  and  verify  that  whether  the 

accessories accord with the requirements of our company. 

  It is necessary to inspect and maintain the medical refrigerator at specified time intervals. 

  The  medical  refrigerator  is  strictly  prohibited  to  store  living  things  or  other  goods  which  have  strict 

temperature requirement and are unsuited for storage at constant temperature. 

  The  medical  refrigerator  realizes  refrigeration  through  the  heat  dissipation  of  the  back  surface 

(condenser). In order to ensure normal operation and ventilation and heat dissipation, the back and the 

left and right sides of the refrigerator body should be at least 30cm away from the wall and no barriers 

are allowed to block the air inlet and the air outlet. 

  In  case  of  machine  fault  or  power  failure,  the  temperature  in  the  medical  refrigerator  will  rise.  If  the 

machine cannot be repaired in short period, please take out the stored goods and transfer them to other 

place where accords with the storing temperature to avoid damages. 

It is used to warn the user that there may be danger of hand pinching in the gap of the product door 

when opening and closing the door

 

It is used to warn users that there may be electric shock hazards in the electrical components and 

connecting wire terminals in the engine room

 

Used to warn users that the refrigerator uses flammable refrigerant and the product should be kept 

away from fire 

Used to warn users that the product fan may hurt their hands when taking things 

 

 

Summary of Contents for MPC-5V100

Page 1: ...ON MANUAL Pharmacy Refrigerator MPC 5V100 VERSION 2020 10 MPC 5V100 The image shown here is indicative only If there is inconsistency between the image and the actual product the actual product shall...

Page 2: ...s goggles etc 2 Always adopt good health habits and operate strictly according to the product instruction 3 Everyone is obliged to be in charge of one own safety 4 Not Allowed direct contact with pati...

Page 3: ...perature The medical refrigerator realizes refrigeration through the heat dissipation of the back surface condenser In order to ensure normal operation and ventilation and heat dissipation the back an...

Page 4: ...3 2 1 Key function 7 3 2 2 Parameter settings 8 3 2 3 Error display 9 IV Routine Maintenance 10 4 1 Clean of incubator 10 4 2 Defrost 10 4 3 Care and maintenance 10 V Clearing of Fault and Maintenanc...

Page 5: ...oduct Diagram Structural diagram Due to the improvement and various models of products the actual product may be different from the diagram please in kind prevail Fan Shelf Glass door Door Lock Contro...

Page 6: ...mber Dismantle all package components including protection foam in the refrigerator body Please check accessories and data according to the packing list Please clean the product before use The product...

Page 7: ...ulator to be used cooperatively When the medical refrigerator is used the power supply is required to be equipped with a lower voltage air circuit breaker and a leakage protection device It is necessa...

Page 8: ...ed to put the goods to be stored in the refrigerator after the inside temperature falls to the operating temperature If there are too much goods to be stored it is advised to store separately for thre...

Page 9: ...mal working of the device such as bad temperature uniformity and abnormal high low temp alarm Notes the general high and low temperature alarm values are within the set temperature range of 2 10 3 2 2...

Page 10: ...emperature sensor goes wrong you should cut off the power and first check whether the connecting wire of the sensor is loose Please contact professional after sales service or distributor of us for pr...

Page 11: ...ged thereby causing faults During the rainy season vapors may be easily condensed on the surface of the glass door of the refrigerator In serious condition water may drip Please use dry cloth to wipe...

Page 12: ...cket is plugged or loosened If the power fuse is disconnected If the supply voltage is too low or too high Compressor breaks down If the temperature setting is right Temperature goes on decreasing aft...

Page 13: ...Main technical parameters 6 2 Electrical schematic diagram VII Packing list Model Temp Volume Power supply Refrigerant Dimension MPC 5V100 2 8 100L 220V 50Hz R600a 505 510 875 Model Operation instruc...

Reviews: