background image

 

 

 

Statement: 

Thank  you  for  buying  our  medical  refrigerator.  For  your  safe  and  convenient  use  and  reasonable 

maintenance of the product, please read the operation instruction carefully and keep it properly for reference. 

For  damages  of  any  instrument  due  to  the  fact  that  the  user  does  not  use  the  product  according  to  the 

instrument operating environment declared in the handbook or injuries due to the fact that individual does not 

operate  the  product  according  to  safety  instructions,  we  have  no  obligations  and  responsibilities  to  be  in 

charge of them. 

The user must accomplish the following three points when using the product: 

1. Always use protective devices correctly (including clothes, gloves, goggles, etc.); 

2. Always adopt good health habits and operate strictly according to the product instruction; 

3. Everyone i

s obliged to be in charge of one’ own safety. 

4.Not Allowed direct contact with patients, use or affect the product and in the product storage items. 

5.Products without sterilization. 

6.The product is used only for storage, not during use with other materials, Organization and Technology in 

combination. 

7.Products can not be used to measure or analysis. 

8.Life and storage life of the products is irrelevant. 

9.Some models need to regularly add supplies, such as printer paper, test tubes, etc. 

10.This product is non-explosion-proof products. 

11.Non flash freeze equipment, is limited to keeping the temperature used. 

Due to our fast product update, there may be differences between function of the product you bought and the 

function mentioned in the instruction, please in kind prevail. 

 

 

 

 

 

 

Summary of Contents for MPC-5V100

Page 1: ...ON MANUAL Pharmacy Refrigerator MPC 5V100 VERSION 2020 10 MPC 5V100 The image shown here is indicative only If there is inconsistency between the image and the actual product the actual product shall...

Page 2: ...s goggles etc 2 Always adopt good health habits and operate strictly according to the product instruction 3 Everyone is obliged to be in charge of one own safety 4 Not Allowed direct contact with pati...

Page 3: ...perature The medical refrigerator realizes refrigeration through the heat dissipation of the back surface condenser In order to ensure normal operation and ventilation and heat dissipation the back an...

Page 4: ...3 2 1 Key function 7 3 2 2 Parameter settings 8 3 2 3 Error display 9 IV Routine Maintenance 10 4 1 Clean of incubator 10 4 2 Defrost 10 4 3 Care and maintenance 10 V Clearing of Fault and Maintenanc...

Page 5: ...oduct Diagram Structural diagram Due to the improvement and various models of products the actual product may be different from the diagram please in kind prevail Fan Shelf Glass door Door Lock Contro...

Page 6: ...mber Dismantle all package components including protection foam in the refrigerator body Please check accessories and data according to the packing list Please clean the product before use The product...

Page 7: ...ulator to be used cooperatively When the medical refrigerator is used the power supply is required to be equipped with a lower voltage air circuit breaker and a leakage protection device It is necessa...

Page 8: ...ed to put the goods to be stored in the refrigerator after the inside temperature falls to the operating temperature If there are too much goods to be stored it is advised to store separately for thre...

Page 9: ...mal working of the device such as bad temperature uniformity and abnormal high low temp alarm Notes the general high and low temperature alarm values are within the set temperature range of 2 10 3 2 2...

Page 10: ...emperature sensor goes wrong you should cut off the power and first check whether the connecting wire of the sensor is loose Please contact professional after sales service or distributor of us for pr...

Page 11: ...ged thereby causing faults During the rainy season vapors may be easily condensed on the surface of the glass door of the refrigerator In serious condition water may drip Please use dry cloth to wipe...

Page 12: ...cket is plugged or loosened If the power fuse is disconnected If the supply voltage is too low or too high Compressor breaks down If the temperature setting is right Temperature goes on decreasing aft...

Page 13: ...Main technical parameters 6 2 Electrical schematic diagram VII Packing list Model Temp Volume Power supply Refrigerant Dimension MPC 5V100 2 8 100L 220V 50Hz R600a 505 510 875 Model Operation instruc...

Reviews: