Notes:  please  note  that  do  not  let  the  power  line  be  damaged  by  trundles  when  pushing  the 

medical refrigerator. 

Notes: be sure to take off the packaging pedestal on the bottom of the medical refrigerator. 

Notes:  Do  not  put  goods  into  the  medical  refrigerator  which  is  just  plugged  in.  Let  the  empty 

body run for 

a while (about 12 hours) and then put the goods to be refrigerated into the refrigerator.   

Normal operating condition of the equipment: 

Environmental temperature: 10

℃~

32

℃;

 

Relative humidity: ≤80

%;

 

There is no strong sharp pounding and corrosive gas around; 

There are no effects of direct radiation of sunshine and other cold and heat sources. 

 

Working system of the medical refrigerator: intermittent running 

Safety precautions 

  Supply voltage: the equipment needs 220V/50Hz alternating current power supply. If the service voltage 

is lower than 187V or higher than 242V, it is necessary to add a proper automatic voltage regulator to be 

used cooperatively; 

  When the medical refrigerator is used, the power supply is required to be equipped with a lower voltage 

air circuit breaker and a leakage protection device; 

  It  is  necessary  to  use  a  dedicated  independent  socket  which  is  grounded  reliably.  The  length  of  the 

power line cannot be lengthened at randomly. If it really needs to be lengthened, be sure to use a cooper 

core conductor which is larger than 2.5mm2. And the cross area of the copper core conductor which is in 

the wall and connected with the power socket must be above 4mm2

 

  Inflammable and explosive dangerous goods and goods of acid and alkali etc. with strong corrosiveness 

are not allowed to be put into the medical refrigerator; 

  Keys  should  be  kept  properly  to  avoid  accidents  that  will  happen  if  children  get  the  key  to  open  the 

door;·he zero line (N end) of the socket cannot be connected with the ground lead (E end). Otherwise, 

the housing of the medical refrigerator may be electrified and electric shock accidents may be caused; 

  The power line cannot be bundled up, pressed under weight and next to heat sources of compressor, 

etc. 

Summary of Contents for MPC-5V100

Page 1: ...ON MANUAL Pharmacy Refrigerator MPC 5V100 VERSION 2020 10 MPC 5V100 The image shown here is indicative only If there is inconsistency between the image and the actual product the actual product shall...

Page 2: ...s goggles etc 2 Always adopt good health habits and operate strictly according to the product instruction 3 Everyone is obliged to be in charge of one own safety 4 Not Allowed direct contact with pati...

Page 3: ...perature The medical refrigerator realizes refrigeration through the heat dissipation of the back surface condenser In order to ensure normal operation and ventilation and heat dissipation the back an...

Page 4: ...3 2 1 Key function 7 3 2 2 Parameter settings 8 3 2 3 Error display 9 IV Routine Maintenance 10 4 1 Clean of incubator 10 4 2 Defrost 10 4 3 Care and maintenance 10 V Clearing of Fault and Maintenanc...

Page 5: ...oduct Diagram Structural diagram Due to the improvement and various models of products the actual product may be different from the diagram please in kind prevail Fan Shelf Glass door Door Lock Contro...

Page 6: ...mber Dismantle all package components including protection foam in the refrigerator body Please check accessories and data according to the packing list Please clean the product before use The product...

Page 7: ...ulator to be used cooperatively When the medical refrigerator is used the power supply is required to be equipped with a lower voltage air circuit breaker and a leakage protection device It is necessa...

Page 8: ...ed to put the goods to be stored in the refrigerator after the inside temperature falls to the operating temperature If there are too much goods to be stored it is advised to store separately for thre...

Page 9: ...mal working of the device such as bad temperature uniformity and abnormal high low temp alarm Notes the general high and low temperature alarm values are within the set temperature range of 2 10 3 2 2...

Page 10: ...emperature sensor goes wrong you should cut off the power and first check whether the connecting wire of the sensor is loose Please contact professional after sales service or distributor of us for pr...

Page 11: ...ged thereby causing faults During the rainy season vapors may be easily condensed on the surface of the glass door of the refrigerator In serious condition water may drip Please use dry cloth to wipe...

Page 12: ...cket is plugged or loosened If the power fuse is disconnected If the supply voltage is too low or too high Compressor breaks down If the temperature setting is right Temperature goes on decreasing aft...

Page 13: ...Main technical parameters 6 2 Electrical schematic diagram VII Packing list Model Temp Volume Power supply Refrigerant Dimension MPC 5V100 2 8 100L 220V 50Hz R600a 505 510 875 Model Operation instruc...

Reviews: