The Z-Bracket Kit is secured on top of the Valley
Bracket as shown using the existing Flange Nut.
Torque to 15 ft.-lbs.
Using the hardware provided in the Z-Bracket Kit, attach
the Ratchet P-Clamp to the Z-Bracket.
Tighten securely.
For more on Ratchet P-Clamps see:
hellermanntyton.us
Two options are available for attaching the
Ratchet P-Clamp, either to the Module Stop
Bracket (above left) or the Tray (above right).
If attaching to the Module Stop Bracket, secure
the Ratchet P-Clamp using the existing Flange
Nut.
Torque to 15 ft.-lbs.
For the Tray attachment, use the hardware provided in the
Z-Bracket Kit. Secure the Z-Bracket to the Tray and then
secure the Ratchet P-Clamp to the top of the Z-Bracket.
Torque to 15 ft.-lbs.
For more on Ratchet P-Clamps see:
hellermanntyton.us
POWER MAX
TM
Accessories Installation Guide, Tilted (5°, 10°), Dual Tilt and Flush Arrays
Installing Ratchet P-Clamps - Conduit & Cable Runs (cont.)
Dual Tilt Array - Utilizing PLP’s Z-Bracket Kit