The Z-Bracket Kit may be secured to either the Front
Bracket (as shown) or the Rear Bracket using the
existing Flange Nut. Torque to 15 ft.-lbs.
Using the hardware provided in the Z-Bracket Kit,
attach the Snake Tray Bracket to the Z-Bracket.
Tighten securely.
Attach the Snake Tray to the Bracket using 5/16 x
3/4” Hex Screw, Flat Washer and Flange Nut.
Tighten securely.
For more on Snake Tray see: snaketray.com
The Z-Bracket Kit is secured on top of the Valley
Bracket as shown using the existing Flange Nut.
Torque to 15 ft.-lbs. .
Using the hardware provided in the Z-Bracket Kit,
attach the Snake Tray Bracket to the Z-Bracket.
Tighten securely.
Attach the Snake Tray to the Bracket using 5/16 x
3/4” Hex Screw, Flat Washer and Flange Nut.
Tighten securely.
For more on Snake Tray see: snaketray.com
Snake Tray
®
is a registered trademark owned by Cable Management Solutions.
POWER MAX™ Accessories Installation Guide, Tilted (5°, 10°), Dual Tilt and Flush Arrays
Installing Snake Tray
®
- Cable Runs
Tilted (5° & 10°) Array - Utilizing PLP’s Z-Bracket Kit
Dual Tilt Array - Utilizing PLP’s Z-Bracket Kit