38 Configuring the iPORT SB-Pro IP Engine
Copyright © 2011 Pleora Technologies Inc.
Implementing the eBUS SDK
You can create your own image acquisition software for the iPORT SB-Pro IP engine. Consult the
eBUS SDK Programmer’s Guide and the eBUS SDK C++ Reference for information about creating
custom image acquisition software.
IP Address Configuration
Initial Selection and Connection
The iPORT SB-Pro IP engine requires an IP address to function on a video network. This address must
be on the same subnet as the PC performing the configuration and receiving the image stream.
To set an initial IP address for the IP engine:
1. Open
GEVPlayer
and click
Select/Connect
.
2. If your device does not appear in the list, click the checkbox,
Show Unreachable GigE Vision
Devices
to show all available devices.
3. Click to select the SB-Pro IP engine in the
Available GigE Vision Devices
window.
4. Click Set IP Address. Provide a valid IP address and subnet mask. You may also optionally
provide a default gateway. Click
OK
to close this window.
5. Click
OK
in the bottom right corner to finish connecting to the IP engine.
Configuring an Automatic/Persistent IP Address
The
GEV Device Control
dialog box allows you to configure a persistent IP address for your iPORT
SB-Pro IP engine. Alternatively, the IP engine can be configured to automatically acquire an IP address
using Dynamic Host Configuration Protocol (DHCP) or Link Local Addressing (LLA). The IP engine
uses its persistent IP address first, but if this option if set to
False
, it can be configured to attempt to
acquire an address from a DHCP server. If this fails, it will use LLA to find an available IP address.
LLA cannot be disabled and is
True
by default.
To automatically configure an IP address:
1. Connect to the iPORT SB-Pro IP engine. Click
GEV Device Control
in the
Parameters and
Controls
section.
2. In the
TransportLayerControl
category, set the
GevCurrentIPConfigurationPersistentIP
feature to
False
.
3. Set the
GevCurrentIPConfigurationLLA
and/or
GevCurrentIPConfigurationDHCP
values to
true, depending on the type of automatic addressing you require.
4. Close the
GEV Device Control
dialog box.
Summary of Contents for iPort SB-Pro
Page 1: ...SB Pro IP Engine For Sony FCB H11 Block Cameras User Guide...
Page 2: ......
Page 3: ...High Performance Imaging Data and Video Over Ethernet...
Page 13: ...13 Copyright 2011 Pleora Technologies Inc PCB Stack C Figure 3 PCB Stack D Figure 4...
Page 19: ...19 Copyright 2011 Pleora Technologies Inc 12 Pin GPIO and Power Connector A Figure 14...
Page 32: ...32 Assembling the iPORT SB Pro IP Engine Copyright 2011 Pleora Technologies Inc...
Page 50: ...50 iPORT SB Pro IP Engine Feature Settings Copyright 2011 Pleora Technologies Inc...
Page 52: ...52 Status LEDs Copyright 2011 Pleora Technologies Inc...