FILLING
We recommend carrying out this operation within two weeks after
installation.
a)
connect the cold water supply line (water works, well,...) to the inflow connection, as
shown in the basic hydraulic connection layout.
Note. The outflow connection must be free; if a discharge tap was installed before the
backflow preventer, it must be opened.
b)
Open the discharge tap installed along the supply line upstream of the inflow
connection, leaving the outflow connection open, and begin loading the accumulation
tank until the water has filled all the cylinders and all the inside air has been bled
through the outflow connection.
Danger! Repeat these filling and bleeding operations, making sure that no
bubbles or pockets of air remain inside the accumulation tank. Any air that remains inside
the system can compromise correct system operation or even damage the collector.
c)
Allow water to flow inside the system for a certain period of time, then rinse the
accumulation tank to free it from any deposits or residues that may have entered during
installation. Direct the outflow water towards a discharge point.
After the product has been filled and started, wait two weeks before drinking
the water.
d)
Close the discharge tap upstream of the cold water and connect the return line to the
backflow preventer, installed on the outflow connection, as shown in the basic hydraulic
connection layout.
e)
Open the cold water discharge tap again: make sure all the safety components have
been assembled correctly, and make sure there are no leaks along the water supply
lines.
Summary of Contents for EGO 110
Page 30: ...Installation and user handbook rev 0 4 of 23 02 2017 30 Installation phases...
Page 31: ...Installation and user handbook rev 0 4 of 23 02 2017 31...
Page 32: ...Installation and user handbook rev 0 4 of 23 02 2017 32...
Page 33: ...Installation and user handbook rev 0 4 of 23 02 2017 33...
Page 34: ...Installation and user handbook rev 0 4 of 23 02 2017 34...
Page 39: ...Installation and user handbook rev 0 4 of 23 02 2017 39 Installation phases...
Page 40: ...Installation and user handbook rev 0 4 of 23 02 2017 40...
Page 41: ...Installation and user handbook rev 0 4 of 23 02 2017 41...
Page 42: ...Installation and user handbook rev 0 4 of 23 02 2017 42...
Page 43: ...Installation and user handbook rev 0 4 of 23 02 2017 43...
Page 44: ...Installation and user handbook rev 0 4 of 23 02 2017 44...
Page 46: ...Installation and user handbook rev 0 4 of 23 02 2017 46...
Page 55: ...Installation and user handbook rev 0 4 of 23 02 2017 55...