7077-801D • September 17, 2019
37
When describing the location of a component,
it is always AS YOU FACE THE FRONT OF THE
APPLIANCE.
1. Control Board
The control board is located on the right side of the
appliance behind the lower right side panel.
2. Convection Blower
The convection blower is mounted in the rear of the
unit. It pushes air up the rear of the firebox, across the
top and out the front. As the air moves past the firebox
it is heated.
3. Exhaust Blower
The exhaust blower is mounted on the left side of the
appliance. The exhaust blower is designed to pull the
exhaust from the appliance and push it out through the
venting system.
4. Feed System
The feed system can be accessed in two areas. To
access the auger spring, remove the cover in the
hopper. To remove the feed motor, remove the side
panel and motor cover plate in the rear of the unit.
5. Firepot
The firepot is made of a combination of stainless steel
and heavy duty cold rolled steel. It is removable to aid
in cleaning.
6. Fuse
The fuse is located on the control board. The fuse
will blow should a short occur and shut off power to
the appliance.
7. Dial Control
The dial control is attached to the right side of the
appliance. The large dial controls the heat output
where as the small dial below the large dial is the
trim feature. The LED blinks according to the state of
the appliance.
8. Hopper Switch
The hopper switch is located in the upper right hand
corner of the hopper. This switch is designed to
shut down the feed motor whenever the hopper lid
is opened.
9. Igniter
The igniter is mounted in the chamber in the rear of the
firebox below the convection blower. Combustion air
travels over the red hot igniter creating super heated
air that ignites the pellets.
10. Power Supply
The power cord connector in the rear of the unit.
Check the wall receptacle for 120 volt, 60 Hz
(standard current). Make sure the outlet is grounded
and has the correct polarity. A good surge protector
is recommended.
A. Component Function
11. Exhaust Probe
The exhaust probe is mounted to the side of the
exhaust outlet in the rear of the unit. It senses the
temperature of the exhaust and allows the control
system to make decisions.
12. Ambient Probe
The ambient probe is located in the back panel. It
has extra wire to increase distance from appliance
if needed.
13. Snap Disc (Back Burn Protector) 200°F
Snap disc is mounted on the back of the auger tube
in the center of the appliance and has a reset button.
There are two grey wires connected to it. To access it
remove the right side panel. If the fire tries to burn back
into the feed system or push exhaust up the feed tube,
this snap disc will shut the entire system off. Unplug
the stove prior to resetting.
14. Vacuum Switch
The vacuum switch is located on the lower right side
of the appliance behind right side panel. There are
two red wires attached to it. This switch turns the feed
system on when vacuum is present in the firebox. The
vacuum switch is a safety device to shut off the feed
motor if the exhaust or the heat exchanger system
is dirty or plugged or if the firebox door is open or
exhaust blower failure.
15. Outside air inlet
The outside air tube can be attached to the 2” OD inlet
tube mounted to the rear of the firebox. To extend the
hose outside the unit there is a knockout plate that
must be removed.
13
Reference Materials