7077-801D • September 17, 2019
(877) 477- 4768
26
*Exception for Horizontal Installations:
CANADA INSTALLATIONS:
A non combustible floor
protections extending beneath the flue pipe is required
with horizontal venting or under the top vent adapter with
vertical installation.
USA INSTALLATIONS:
A non-combustible floor protection
extending beneath the flue pipe is recommended with
horizontal venting or under the top vent adapter with
vertical installation.
A non combustible floor protector is required.
E. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance “M” from the surface of the
glass door.
Hearth Pad Requirements
Inches
K
Sides
2
L*
Back
2
M
Front
6
Hearth Pad Requirements
Millimeters
K
Sides
203
L*
Back
51
M
Front
152
USA Hearth Pad Requirements
Canada Hearth Pad Requirements
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
L*
K
M
K
WARNING
If the information in these instructions
is not followed exactly, a fire may result
causing property damage, personal injury,
or death.
•
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
•
Do not over fire - If heater or chimney connector
glows, you are over firing. Over firing will void
your warranty.
•
Comply with all minimum clearances to
combustibles as specified. Failure to comply may
cause house fire.