7077-801D • September 17, 2019
21
1. Open the door from the appliance by lifting door off of
hinge pins and lay on a flat surface face down.
2. Using a Phillips Head screw driver, remove the 3
brackets and set aside.
3. Remove old glass and replace with the new glass.
4. Re-install the brackets using the same screws.
1. Turn the dial control to the off position. Unplug the
power to the unit.
2. Unplug the wires from the control board. The
connectors are locking connectors. Pinch the release
tab on each connector and gently tug and rock loose.
3. Pinch the 4 plastic pins from the rear of the unit to
release the control board connectors.
4. Install new board following the steps in reverse.
1. Turn the dial control to the off position. Unplug the
power to the unit.
2. Pull the plastic fuse holder cover off the control board.
3. Replace fuse with 5AMP 120VAC fuse only.
4. Replace the cover on the fuse holder and restart unit.
1. Turn the dial control to the off position and unplug the
unit. Remove the right side panel and feed motor cover
plate in the rear of the unit.
2. Unplug the connector from the feed motor.
3. Using pliers, remove the cotter pin.
4. Remove the feed motor from the feed shaft.
5. Reinstall the new feed motor by aligning the clearance
hole in the feed motor shaft with the auger spring shaft.
6. Plug the feed motor leads back in and restore power.
1. Empty the hopper of all pellets then follow the steps to
remove the feed motor above.
2. Remove the four screws holding the feed motor
bracket on.
3. Slide the auger assembly out from the bottom in the
rear of the unit.
4. Inspect the bronze bearings, replace if needed.
5. Install new spring assembly following reverse steps
including reattaching the feed motor.
F. Glass Replacement
G. Control Board Replacement
H. Fuse Replacement
I. Feed Motor Replacement
J. Feed Spring Replacement
•
Glass is 5mm thick high temperature
heat-resistant ceramic glass.
•
DO NOT REPLACE with any
other material.
•
Alternate material may shatter and
cause injury.
WARNING