User’s Manual of IAP-200x Series
-19-
Figure 2-16
Plug in the SFP transceiver
Before connect the other switches, workstation or Media Converter,
1. Make sure both side of the SFP transceiver are with the same media type or WDM pair, for example:
100Base-FX to 100Base-FX, 100Base-BX20-U to 100Base-BX20-D.
2. Check the fiber-optic cable type match the SFP transceiver model.
To connect to
MFB-FX
SFP transceiver, use the
multi-mode
fiber cable- with one side must be male
duplex LC connector type.
To connect to
MFB-F20/F40/F60/FA20/FB20
SFP transceiver, use the
single-mode
fiber cable-with
one side must be male duplex LC connector type.
Connect the fiber cable
1. Attach the duplex LC connector on the network cable into the SFP transceiver.
2. Connect the other end of the cable to a device – switches with SFP installed, fiber NIC on a workstation or a
Media Converter.
3. Check the LNK/ACT LED of the SFP slot of the switch / converter. Ensure that the SFP transceiver is
operating correctly.
4. Check the Link mode of the SFP port if the link failed. Co works with some fiber-NICs or Media Converters,
set the Link mode to “100 Force” is needed.
2.4.2. Removing the Module
1. Please make sure there is no network activity by console or check with the network administrator. You can
access the management interface of the Industrial Access Point to disable the port in advance.
2. Remove the Fiber Optic Cable gently.
3. Turn the handle of the MFB module to horizontal.
4. Pull out the module gently through the handle.