background image

  19 

  

  

Conf

orm

ity

Declaration of Conformity

Manufacturer's Name:

Planar Systems, Inc.

Manufacturer's Address:

1195 NW Compton Drive 
Beaverton, OR 97006 

declares that the products

Model Numbers:

c50RP/c67RP, c50RX/c67RX (DLP projection display)

conforms with the provisions of:

Council Directive 89/336/EEC and amended by 92/31/EEC and 93/68/EEC on Electromagnetic Compatibility;

EN55022:1998 Radiated and Conducted Emissions from IT Equipment

EN55024:1998 Immunity of IT Equipment

Including:

EN61000-4-2

Electrostatic Discharge

EN61000-4-3

Radiated Immunity

EN61000-4-4

Electrical Fast Transients

EN61000-4-5

Line Surge

EN61000-4-6

RF Conducted Susceptibility

EN61000-4-8

Magnetic Field Immunity

EN61000-4-11

Voltage Dips and Interrupts

And: 

EN61000-3-2

Harmonic Current Emissions

EN61000-3-3

Voltage fluctuations and Flicker 

Council Directive 73/23/EEC and amended by M1 and C1 on Low Voltage Equipment Safety:

EN60950:2001 Safety of IT Equipment

The Technical Construction File required by this Directive is maintained at the corporate headquarters of Planar Systems, Inc., 1195 NW Compton Drive, Beaverton, 
OR 97006.

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his own expense.

Industry Canada (ICES-003): This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Any changes or modifications to the display not expressly approved by Planar could void the user's authority to operate this equipment.

Other Certifications: CE

Summary of Contents for c50RP

Page 1: ...ne 1 503 748 5799 Toll free Phone 1 866 PLANAR1 752 6271 Email planarsupport planar com Contents 1 Product Safety Information 2 Planning for Your Installation 3 Checking Accessories 4 Installing the O...

Page 2: ...our physical health and safety are important Take a few minutes to read this section at least once Note The plug on the power cord serves as the disconnect for this product No user serviceable parts a...

Page 3: ...ation Configuration Guide CD Have the following tools available String to check the straightness across the fronts of the units Long carpenter s level 48 or longer if possible Steel tape measure to ch...

Page 4: ...in a separate accessory kit Bottom Row Screen Support If you have a wall higher than two units this support provides additional wall stability Brackets The following brackets are available Center Scre...

Page 5: ...off the power on the c50R c67R and remove the power cord WARNING Always turn off power and remove the power cord when adding or removing an electronic part 3 Remove the two screws and the small plate...

Page 6: ...te may be stuck to some EMI tape Try not to tear the tape 7 Remove the cover of the control board It is a snug fit Installing the VIM 1 Slide the VIM in its space and press it into its connector on th...

Page 7: ...here will multiply as the wall goes up Installing the Second and Subsequent Rows 1 Unpack only the displays that will be in this row page 2 2 Make sure all VIMs and Option keys are installed on each...

Page 8: ...r mally do this before you install the c50R c67R in a wall 1 From the rear remove the back panel 2 Remove the shipping foam from the back of the unit the large piece first and then the small wedge 3 U...

Page 9: ...a time with one person holding still and the other person hanging the screen on the hook 6 Press the heel of your hand against all four corners of the screen until the spring loaded latches click int...

Page 10: ...ts does change what comes out of it The selected picture from either Analog In or Digital In always comes out the Digital Out connector in digital form Note The Digital Out signal does not strictly co...

Page 11: ...e Power Supply Most UPS devices will work with the c50R c67R Review the power specifications of your UPS device to make sure it is compatible with the c50R c67R Turning Power On Off 1 With the power c...

Page 12: ...tions See explanations next to the remote control pic ture on this page for additional navigation information Some of the setups described in this Quick Start Guide will explain how to navigate throug...

Page 13: ...press ENTER The PIC TURE menu changes to display the settings for that source When the Source is Familiar to c50R c67R When a new source is selected the c50R c67R looks through a list of the last 10...

Page 14: ...isplay an all white picture from the source computer 5 In the INPUT LEVELS menu select AUTO WHITE LEVEL and press ENTER Wait for Working to disappear 6 The c50R c67R is now adjusted to the black and w...

Page 15: ...Generation Equip ment you can use it to adjust bright ness Pluge is used to calibrate the black level on a video monitor 7 Although it s not required it is recommended that you save the configura tion...

Page 16: ...s use the internal Test Patterns for color balancing not an external pattern 4 When all displays are white find the least bright display in the array This will be the baseline display and you will not...

Page 17: ...solid color contact Pla nar s Technical Support Department The source absent pane is not visible The source is displaying a solid color or a test pattern 4 Ensure the power cable is con nected and th...

Page 18: ...amp remove the three thumb screws and bracket above the lamps 6 Loosen the three captive thumb screws on top of the lamp 7 Lift the wire handle and pull the lamp straight up and out 8 The picture see...

Page 19: ...1 Using the remote turn off the lamp and allow the cooling fans to stop about one minute before proceeding 2 Remove the front screen 3 Loosen the captive screws at the top and bottom of the control b...

Page 20: ...ical Construction File required by this Directive is maintained at the corporate headquarters of Planar Systems Inc 1195 NW Compton Drive Beaverton OR 97006 Note This equipment has been tested and fou...

Reviews: