background image

Pizzato Elettrica Srl
via Torino, 1
36063 MAROSTICA (VI)
ITALY

e-mail: [email protected]
web site:  www.pizzato.com

Phone:   +39.0424.470.930

ZE FOG123B20-EU

5/16

 1 INFORMATION ON THIS DOCUMENT

1.1 Function

The present operating instructions provide information on installation, connection and 
safe use for the following articles: 

CS MP310•0.

1.2 Target audience

The operations described in these operating instructions must be carried out by quali-
fied personnel only, who are fully capable of understanding them, and with the techni-
cal qualifications required for operating the machines and plants in which the safety 
devices are to be installed.

1.3 Application field

These instructions apply exclusively to the products listed in paragraph Function, and 
their accessories.

1.4 Original instructions

The Italian language version is the original set of instructions for the device. Versions 
provided in other languages are translations of the original instructions.

 2 SYMBOLS USED

 This symbol indicates any relevant additional information

 Attention: Any failure to observe this warning note can cause damage or mal-

function, including possible loss of the safety function.

 3 DESCRIPTION

3.1 Device description

The safety device described in this manual is defined according to the Machinery 
Directive 2006/42/EC as logic component for safety functions.
This multifunction safety module is used to implement safety functions such as emer-
gency stop monitoring, door or guard control, monitoring safety barriers, safety mats 
or magnetic sensors on industrial machines. This device is particularly suitable for 
controlling machines with a variety of combined safety functions (for example, simul-
taneous emergency stop and guard control), or machines with parts that have to be 
isolated in normal operating conditions (to do maintenance for example).

3.2 Device functions

This multifunction safety module has many different inputs, which are evaluated by an 
application program to activate safety or signalling outputs. To reach the highest levels 
of safety, this device has a redundant and self monitoring structure with two proces-
sors that continuously check the system in a coordinated way. The module also has 
numerous green LEDs that show the state of the inputs and outputs and two red/blue 
LEDs (P1, P2) that show the state of the processors or any faults.
In the safe state, the safety outputs are switched off (safe power off).
The safety function performed by the module is set up and configured using the logical 
blocks available in the Gemnis Studio configuration software, which is distributed as 
freeware by Pizzato Elettrica and which must be installed on an external PC. A general 
safety function can be defined as follows:
- the safety outputs are switched off within the specified reaction time if the result of 

the programmable logic solver (application program) is negative or in the case of 
errors.

On the basis of external device features and the circuit structure, with this module you 
can obtain safety circuits up to:
- SIL 3 acc. to EN 62061;
- PL e acc. to EN ISO 13849;
- safety category 4 acc. to EN ISO 13849-1.

3.3 Intended use of the device

- The device described in these operating instructions is designed to be applied on 
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be 
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating 
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be 
considered unintended by the manufacturer. 
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications 
to it;
b) using the product in a field of application other than as described in paragraph 
TEChNICAL DATA.

 4 OPERATION

4.1 Definitions

- Application program: the part of the internal safety module software intended for the 

customer's application.

- POwER ON: the safety module state, which lasts from the power on until the end of 

the internal controls.

- RUN: the safety module state on completion of the POwER ON phase (if no errors 

have been detected) in which the application program is run.

- ERROR: the safety module state when a fault is detected. In this state, the module 

switches to the safe state, i.e., all safety outputs are deactivated.

- Fault: a fault can be internal or external to the safety module. Internal faults are 

autonomously detected thanks to its redundant and self-monitored structure. An 
external fault can be detected by the application program. It follows that the definition 
of external fault is strictly dependent on the application (see note A).

4.2 Description of operation

when supplied with power, the module enters the POwER ON state and runs an inter-
nal self-diagnosis. In this phase, the two processor LEDs (P1, P2) remain illuminated 
red for about 1 second. If the internal tests are completed without malfunction, the 
two LEDs are switched off, the module enters the RUN state, and runs the application 
program. If the start tests are not passed, the module enters the ERROR state and the 
malfunction is indicated by the processor LEDs (P1, P2) remaining illuminated in red.
The green LEDs relating to the power supply and the module inputs are not controlled 
by processors, and they immediately begin indicating the states of the respective in-
puts/outputs.
when the module is in the RUN state, and no faults are detected, the two LEDs (P1, 
P2) remain switched off.
In the RUN state, the module can detect faults external to the module, for example 
caused by short circuits, or invalid input states (see note A). Depending on the fault 
type detected, the application program may place the module in ERROR state, to 
indicate the malfunction. In this case, the application program can communicate an 
error code by making the LEDs (P1, P2) flash in sequence.
During the Run state, simultaneously with application program execution, the module 
constantly runs a series of internal tests to check for correct hardware operation. If a 
malfunction is detected, the module state changes to ERROR.
Once in ERROR state, the module is placed in a safe condition, that is with all the 
safety outputs open; the application program is no longer evaluated, and neither are 
the system inputs. Furthermore, the semiconductor signalling outputs are left unal-
tered (changes in inputs do not affect them) at the value imposed by the application 
program before entering the ERROR state. To reset the module, just switch it off for the 
required duration (see technical data) and then switch it on again.

Note A:

 A short circuit is not always a fault. For example, in the case of an ordinary push button for 

emergency stops equipped with two NC contacts, contact opening is the signal to be evaluated and 
a short circuit between the two contacts is a fault. In contrast, in the case of a safety mat with 4-wire 
technology, the opposite is true, i.e. a short circuit between the wires is the signal to be evaluated 
whereas wire interruption is a fault.

4.3 Wiring diagrams
4.3.1 Safe detection of rotating axes motion (up to 4 axes)

A4

F1A

F1B

F2A

F2B

CS MP310•0   

A3

axis 1

axis 2

axis 3

axis 4

F3A

F3B

F4A

F4B

-

+

LED F•A

LED F•B

Description

/

/

No supply voltage on the module.

green

green

Module starting phase

orange

orange

Internal tests upon start-up.

green

*

The sensor connected to terminal F•A has been detected as active.

*

green

The sensor connected to terminal F•B has been detected as active.

blinking  

green

blinking  

green

When the axes are rotating, LEDs F•A and F•B blink green with 
the same frequency as the signal received at the proximity sensor 
inputs, and the voltage detected at terminals A3-A4 is correct.

red / green,  

alternating

red / green,  

alternating

The voltage detected at terminals A3-A4 is not within the allowed 
range (e.g.: terminal detachment, faulty sensors).

red

 red

Internal board error.

Legend: 

 

/ = off;  

* = indifferent

- Only PNP-type proximity sensors can be used.
- The duty cycle of each cam must be such that at least one of the two sensors is 

always active.

- To avoid sensor activation errors, adopt suitable assembly procedures to prevent 

foreign bodies getting between the proximity sensors and the cams.

- Fit the two proximity sensors of the same axis so they are mechanically independent 

of each other. This prevents a simultaneous failure of both sensors. Don't fix both 
sensors to the same bracket for example.

- To detect the direction of rotation, the two sensors of the same axis must be mounted 

with an angle of less than 90°, while guaranteeing at least one sensor is always ac-
tive during axis rotation, as this requirement must be met. Suggested value: 30-50°.

- The direction of rotation of each axis must be checked on the machine to make sure 

Summary of Contents for CS MP310 Series

Page 1: ...l modulo di sicurezza che orientata all applicazione del cliente Power On lo stato del modulo di sicurezza che dura dal momento dell accensione fino alla fine dei controlli interni Run lo stato del mo...

Page 2: ...llo specificato il dispositivo potrebbe non fornire una protezione efficace per l operatore La categoria di sicurezza del sistema secondo EN ISO 13849 1 comprendente il dispositivo di sicurezza dipend...

Page 3: ...nto esterno 3 interno 2 Tensione ad impulso Uimp 0 8 kV Tensione nominale di isolamento Ui 32 V Categoria di sovratensione II Distanze in aria e superficiali secondo EN 60947 1 9 3 Alimentazione A1 A2...

Page 4: ...piego i dettagli su controlli esterni le informazioni sull installazione e il funzionamento sono forniti al meglio delle nostre conoscenze Ad ogni modo ci non significa che dalle caratteristiche descr...

Page 5: ...n this state the module switches to the safe state i e all safety outputs are deactivated Fault a fault can be internal or external to the safety module Internal faults are autonomously detected thank...

Page 6: ...directive requirements The documents necessary for a correct installation and maintenance are always available in the following languages English French German and Italian This device can only be ins...

Page 7: ...12 24 V On Galvanic separation no Minimum duration of input signal 10 ms Input signal filtering yes maximum interference period 0 4 ms Maximum input resistance 100 Maximum input capacitance 470 nF to...

Page 8: ...users are not absolved from the obligation to read and understand our information and recommendations and pertinent technical standards before using the products for their own purposes Taking into acc...

Page 9: ...e celui qui est d crit dans le paragraphe Caract ristiques techniques 4 FONCTIONNEMENT 4 1 D finitions Programme d application partie du logiciel interne du module de s curit qui est orient e vers l a...

Page 10: ...tif en aucun cas Le dispositif sert prot ger les op rateurs Une mauvaise installation ou une mani pulation intempestive peuvent causer de graves blessures voire la mort des dom mages mat riels et des...

Page 11: ...RISTIQUES TECHNIQUES 9 1 Bo tier Mat riau Polyamide PA 66 autoextinguible V0 selon UL 94 Degr de protection IP40 bo tier IP20 bornier Section des c bles 0 2 2 5 mm2 24 12 AWG Couple de serrage des bo...

Page 12: ...us r serve d erreurs et de modifications sans pr avis Les donn es pr sent es dans ce docu ment sont soigneusement contr l es et constituent des valeurs typiques de la production en s rie Les descripti...

Page 13: ...des Ger ts in einem Anwendungsbereich der im Abschnitt Techni sche Daten nicht aufgef hrt ist 4 BETRIEB 4 1 Definitionen Anwendungsprogramm der auf die Anwendung des Kunden ausgerichtete Teil der inte...