Pitco L20-281 Installation And Operation Manual Download Page 2

THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE 

 

 

 
 

FOR YOUR SAFETY 

DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of 
this or any other appliance. 

 
 
 

WARNING 

Improper installation, alteration, service or maintenance can cause property damage, 
injury or death. Read the installation, operating and maintenance instructions 
thoroughly before installing or servicing this equipment. 

 

TO THE PURCHASER 

Post in a prominent location the instructions 
to be followed in the event that an operator 
smells gas. Obtain this information from 
your local gas supplier. 

 

WARNING 

There is an open flame inside this appliance. 
The unit may get hot enough to set nearby 
materials on fire. Keep the area around the 
appliance free from combustibles. 

 

WARNING 

DO NOT

 supply the appliance with a gas 

that is not indicated on the data plate. If you 
need to convert the appliance to another 
type of fuel, contact your dealer. 

 

WARNING 

DO NOT 

use an open flame to check for 

gas leaks! 

 

WARNING 

If gas flow to appliance is interrupted, or pilots 
extinguish, wait 5 minutes before attempting to 
relight the pilot to allow any residual gas in 
appliance to dissipate. 
 

WARNING 

Ensure that the appliance can get enough air to 
keep the flame burning correctly. If the flame is 
starved for air, it can give off a dangerous carbon 
monoxide gas. Carbon monoxide is a clear 
odorless gas that can cause suffocation. 

 

WARNING 

 

Adequate means must be provided to limit the 
movement of this appliance without depending on 
the gas line connection. Single appliances 
equipped with legs must be stabilized by installing 
anchor straps. All appliances equipped with 
casters must be stabilized by installing restraining 

chains. If a flexible gas line is used, an additional 
restraining cable must be connected at all times 
when the appliance is in use. 

 

WARNING 

An appliance equipped with casters and a flexible 
gas line must be connected to the gas supply with 
a quick disconnect device. This quick disconnect 
must comply with ANSI Z24.41. To limit the 
movement of the appliance without depending on 
the connector or quick disconnect, a restraining 
cable must also be installed. 

 

WARNING 

Models with electric controls are equipped with an 
oil proof electrical supply cord, with a three-prong 
safety plug. This is to protect operators from 
electrical shock hazard in the event of an 
equipment malfunction. DO NOT cut or remove the 
grounding (third) prong from this plug. 

 

WARNING 

This appliance, when installed, must be electrically 
grounded in accordance with local codes, or in the 
absence of local codes, with the 

National Electrical 

Code, ANSI/NFPA 70, or the Canadian Electrical 
Code, CSA C22.2, 

as applicable. 

 

WARNING 

The power supply must be disconnected before 
servicing or cleaning this appliance. 

 

WARNING 

Do not attempt to move this appliance when the 
unit is at operating temperature. Serious personal 
injury could result if skin comes in contact with the 
hot surfaces. 
 

WARNING

 

DO NOT sit or stand on this appliance. Serious 
injury could result from falling or contact with hot 
shortening/oil. 

Summary of Contents for L20-281

Page 1: ...e this information and retain this manual for the life of the equipment Model __________________________ Serial __________________________ Date Purchased ___________________ Installation and Operation...

Page 2: ...rovided to limit the movement of this appliance without depending on the gas line connection Single appliances equipped with legs must be stabilized by installing anchor straps All appliances equipped...

Page 3: ...is completely assembled The fryer will need to be leveled once it is in place Leveling the fryer is done with a large pair of water pump pliers The casters provide the necessary height to meet sanita...

Page 4: ...when pressure is applied ELECTRICAL CONNECTION The electrical service used by the fryer must comply with local codes If there are no local codes that apply refer to the National Electrical Code NEC A...

Page 5: ...s a list of reference documents that provide guidance on ventilation and fire safety systems This table is notnecessarilycomplete Additionalinformationcanbeobtained fromCSAInternational 8501EastPleasa...

Page 6: ...te WARNING DONOTTURNCOMBINATIONGASVALVEKNOBTOTHE ON POSITIONUNTIL VESSELISFULLOFWATERORSHORTENING TURNINGTHEKNOBTO ON WITHVESSEL EMPTYWILLDAMAGETHEVESSELORCOMPONENTSANDVOIDWARRANTY INITIALCLEANING Whe...

Page 7: ...ndcompletelypackfrytankuptooillevelmarkwith cubes making sure there are no air pockets c Computer Controller Press the button on the controller panel to turn fryer ON Note if using solid shortening en...

Page 8: ...n is only large enough to hold the contents of one 1 tank at once during the filter process d When the tank is empty close the green handled drain valve Open the red handled return valve to the tank y...

Page 9: ...debriswhichcouldcausethepaperandholddownring not to seat properly Place the Paper Support Screen in the bottom of the pan Place filter Paper or Pad over screen making sure that there is an equal amoun...

Page 10: ...from the fryer WARNING Do not use the filter pan to drain cleaning water into The only way to remove liquid from the filter pan is via the filter pump Do not use the filter pump to pump water Water ca...

Page 11: ...his information and retain this manual for the life of the equipment Model __________________________ Serial __________________________ Date Purchased ___________________ Manuel d Installation Et de F...

Page 12: ...Toute mauvaise installation alt ration reparation et tout mauvais r glage ou entretien risque de provoquer des d g ts mat riels des blessures graves voire la mort Veuillez lire attentivement les manue...

Page 13: ...gants tanches l huile lorsque vous transportez ou d placeztoutappareilouliquidechaud Mise niveau Votre friteuse est d j compl tement assembl e sa r ception Une fois en place la friteuse doit tre mise...

Page 14: ...ue national des tats Unis NEC et aux normes ANSI NFPA pour l installation lectrique Au Canada reportez vous la norme CSA C22 1 et la r glementation de votre localit Les diagrammes dec blagessontvisibl...

Page 15: ...entilation et les syst mes de protection contre les incendies Cette liste n est pas compl te Il vous est possible d obtenir des informations suppl mentaires aupr s de l CSA International 8501 East Ple...

Page 16: ...elafriteuseestexp di e ellecomportedenombreusespi cesrecouvertesd unefinepelliculed huileafind assurer leur protection Avant que la friteuse ne soit pr te tre utilis e elle doit tre nettoy e Vous reti...

Page 17: ...EMENT Toutefriteuse gaz roulettesdoit tre quip ed undispositifderetenue Cedispositifdes curit doit treraccord toutmomentafinquelafriteusesoitraccord e laconduited arriv edegaz Sipouruneraisonquelconqu...

Page 18: ...tion d huile REMARQUE Ce bac de filtrage ne peut accueillir le contenu d une seule cuve la fois lors du filtrage d Apr s avoir vid la cuve fermez le robinet de purge vert Ouvrez la vanne de retour rou...

Page 19: ...de la bague de retenue Placez le tamis du support du papier sur le bas du r cipient du filtre Placez le papier ou le tampon du filtre sur le tamis en veillant ce que chaque c t comporte une certaine...

Page 20: ...rez le de la friteuse AVERTISSEMENT Nepasutiliserlebacdefiltrageafindevidangerl eaudenettoyage Retirezleliquidedubacde filtrageparl interm diairedelapompedefiltrage Nepasutiliserlapompedefiltrageafind...

Reviews: