FRYER CLEANING
Daily

Your fryer should be clean every day to maintain peak performance and appearance.  Perform the procedures below
every day.

a.  Wipe up any shortening that spills onto the exterior of the fryer.  This should be done with a clean soft cloth
     while the oil is still warm.
b. Use warm water with a mild detergent to clean surfaces.  Be careful not to get water in the shortening and to
    remove any detergent from the fry tank.
c. Use a nonabrasive scouring powder or pad to clean stains if necessary.

Weekly (Boilout)

The fryer should be thoroughly cleaned once a week.  This cleaning should include a complete draining of the fryer
and a boil out.  This would also be a good time to check the filter media for damage.

CAUTION

Completely shut down the fryer when the oil is to be replaced by water, and
when the heating portion of the cleaning is complete.  This will prevent the
heating system from coming on during the oil draining and water filling
procedure.

a.  Drain the oil from the fryer using the fryer drain procedures.  When the oil  has been pumped into the oil shuttle,
    disconnect the filter pan and remove from the fryer.

WARNING

Do not use the filter pan to drain cleaning water into.  The only way to remove
liquid from the filter pan is via the filter pump.  Do not use the filter pump to
pump water.  Water can remain in the filter lines and mix with hot oil during
filter procedures creating a problem.

b.  Remove tube rack/mesh tube screens and remove any large debris from the bottom of the fry tank.  Close
    the drain valve and fill the fry tank with water and noncaustic detergent.  For best results use Pitco Fryer
    Cleaner part number P6071397.

c.  Place a large pan under the drain.  This pan will be used to catch the cleaning water.  The pan must be of
    sufficient size to hold all of the water.

d.  Restart your fryer.  When the water temperature reaches 212°F the computer will automatically go into Boil
     mode.   To get the fryer out of BOIL mode you must turn the fryer power off.

e.  After the water has reached a slow boil, turn the fryer off.  Allow the fryer to soak for 20 minutes to soften
     shortening deposits and carbon.  Use fryer brush to remove any residue from tank, heating tubes, and side
     walls.  Perform the daily cleaning procedures.

f.  Drain the water into the pan by slowly opening the green handled drain valve.

g.  Wipe the tank dry with clean cloth wipes.  Close the drain valve and remove the large container.

h.  Refill the fryer.

Summary of Contents for L20-281

Page 1: ...e this information and retain this manual for the life of the equipment Model __________________________ Serial __________________________ Date Purchased ___________________ Installation and Operation...

Page 2: ...rovided to limit the movement of this appliance without depending on the gas line connection Single appliances equipped with legs must be stabilized by installing anchor straps All appliances equipped...

Page 3: ...is completely assembled The fryer will need to be leveled once it is in place Leveling the fryer is done with a large pair of water pump pliers The casters provide the necessary height to meet sanita...

Page 4: ...when pressure is applied ELECTRICAL CONNECTION The electrical service used by the fryer must comply with local codes If there are no local codes that apply refer to the National Electrical Code NEC A...

Page 5: ...s a list of reference documents that provide guidance on ventilation and fire safety systems This table is notnecessarilycomplete Additionalinformationcanbeobtained fromCSAInternational 8501EastPleasa...

Page 6: ...te WARNING DONOTTURNCOMBINATIONGASVALVEKNOBTOTHE ON POSITIONUNTIL VESSELISFULLOFWATERORSHORTENING TURNINGTHEKNOBTO ON WITHVESSEL EMPTYWILLDAMAGETHEVESSELORCOMPONENTSANDVOIDWARRANTY INITIALCLEANING Whe...

Page 7: ...ndcompletelypackfrytankuptooillevelmarkwith cubes making sure there are no air pockets c Computer Controller Press the button on the controller panel to turn fryer ON Note if using solid shortening en...

Page 8: ...n is only large enough to hold the contents of one 1 tank at once during the filter process d When the tank is empty close the green handled drain valve Open the red handled return valve to the tank y...

Page 9: ...debriswhichcouldcausethepaperandholddownring not to seat properly Place the Paper Support Screen in the bottom of the pan Place filter Paper or Pad over screen making sure that there is an equal amoun...

Page 10: ...from the fryer WARNING Do not use the filter pan to drain cleaning water into The only way to remove liquid from the filter pan is via the filter pump Do not use the filter pump to pump water Water ca...

Page 11: ...his information and retain this manual for the life of the equipment Model __________________________ Serial __________________________ Date Purchased ___________________ Manuel d Installation Et de F...

Page 12: ...Toute mauvaise installation alt ration reparation et tout mauvais r glage ou entretien risque de provoquer des d g ts mat riels des blessures graves voire la mort Veuillez lire attentivement les manue...

Page 13: ...gants tanches l huile lorsque vous transportez ou d placeztoutappareilouliquidechaud Mise niveau Votre friteuse est d j compl tement assembl e sa r ception Une fois en place la friteuse doit tre mise...

Page 14: ...ue national des tats Unis NEC et aux normes ANSI NFPA pour l installation lectrique Au Canada reportez vous la norme CSA C22 1 et la r glementation de votre localit Les diagrammes dec blagessontvisibl...

Page 15: ...entilation et les syst mes de protection contre les incendies Cette liste n est pas compl te Il vous est possible d obtenir des informations suppl mentaires aupr s de l CSA International 8501 East Ple...

Page 16: ...elafriteuseestexp di e ellecomportedenombreusespi cesrecouvertesd unefinepelliculed huileafind assurer leur protection Avant que la friteuse ne soit pr te tre utilis e elle doit tre nettoy e Vous reti...

Page 17: ...EMENT Toutefriteuse gaz roulettesdoit tre quip ed undispositifderetenue Cedispositifdes curit doit treraccord toutmomentafinquelafriteusesoitraccord e laconduited arriv edegaz Sipouruneraisonquelconqu...

Page 18: ...tion d huile REMARQUE Ce bac de filtrage ne peut accueillir le contenu d une seule cuve la fois lors du filtrage d Apr s avoir vid la cuve fermez le robinet de purge vert Ouvrez la vanne de retour rou...

Page 19: ...de la bague de retenue Placez le tamis du support du papier sur le bas du r cipient du filtre Placez le papier ou le tampon du filtre sur le tamis en veillant ce que chaque c t comporte une certaine...

Page 20: ...rez le de la friteuse AVERTISSEMENT Nepasutiliserlebacdefiltrageafindevidangerl eaudenettoyage Retirezleliquidedubacde filtrageparl interm diairedelapompedefiltrage Nepasutiliserlapompedefiltrageafind...

Reviews: