28
EN
Pai
ring
/C
al
ib
ra
tion
Calibrating the sensors (zero point calibration)
Checking the Zero Point
1. Position the crank arm so
it is perpendicular to the
ground, pointing downward.
2. Select [Calibration] in the
main menu of SGX-CA600.
3. Confirm the value in [Status].
Make sure that the [Tangential Line]
and [Normal Line] values are as
shown here.
•
Tangential Line: 0 ± 3 N
•
Normal Line: 0 ± 3 N
Calibration method in
power meter mode using a
cyclocomputer from another
manufacturer
For how to calibrate, refer to the User’s
Manual of the cyclocomputer you are
using.
Summary of Contents for SGY-PM930H
Page 34: ...34 ...
Page 67: ...67 ...
Page 100: ...100 ...
Page 133: ...133 ...
Page 166: ...166 ...
Page 199: ...199 ...
Page 225: ...225 JP 準 備 5 製品天面の 決定 ボタンにて数値を変更する 左右を間違えて設定した場合 正しい パワー表示ができなくなりますのでご 注意ください ...