PDP-5050SX
97
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Audio Level Adjustment
Equipment : SG, Digital mutimeter / Tester
Condition : Input RF level 60dB
µ
V
1kHz MONO 100%
VR7504
(AV BOARD Assy)
TP7504
(AV BOARD Assy)
Digital multimeter
/ Tester
START
Adjust TP7504 to 110mVrms
3
Select
55.25 MHz
ANT B
AIR
02
1
9
MSP Adjustment
Equipment : SG, Oscilloscope
Condition : Input RF level 60dB
µ
V
300Hz STEREO 100% Lch Only
VR7506
(AV BOARD Assy)
START
4
Oscilloscope
CH1
CH2
(X)
(Y)
TP7503
(AV BOARD Assy)
Adjust
Turn the wave pattern into a minimum.
minimum
Select
67.25 MHz
ANT A
AIR
04
1
9