83
RS-232C Adjustment Mode
74. PICTURE Size
Function
Screen mode selection.
Transmit Data
DFH
80H
60H
2AH
01H
DATA00
CKS
DATA00
01H : ON
02H : OFF
ACK
7FH
60H
80H
2AH
01H
DATA00
CKS
DATA00
01H : ON
02H : OFF
75. OPTION Select
Function
It sets power on mode, key lock, and wireless remote
control.
Transmit Data
DFH
80H
60H
63H
04H
DATA00–DATA03
CKS
DATA00 : power on mode
00H : last memory
01H : video 1
02H : video 2
03H : video 3
05H : COMPNT1
06H : COMPNT2
(SCART1/SCART2)
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
0DH : COMPNT3 (SCART3)
DATA01 : key lock
00H : OFF
01H : ON
DATA02 : wireless remote control
00H : OFF
01H : ON
DATA03 : loop out
00H : OFF
01H : ON
ACK
7FH
60H
80H
63H
00H
CKS
* “SCART1, 2, 3” function is only PDP-61MXE1.
76. REPEAT Timer
Function
The external control apparatus sets the REPEAT Timer of
the display.
Transmit Data
DFH
80H
60H
64H
07H
DATA00–DATA06
CKS
DATA00
00H : repeat timer off
01H : repeat timer on
DATA01
PROGRAM 1
01H : screen division 1
02H : screen division 4
03H : screen division 9
DATA02
SOURCE
01H : video 1
02H : video 2
03H : video 3
05H : COMPNT1
06H : COMPNT2 (SCART1/SCART2)
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
0DH : COMPNT3 (SCART3)
DATA03
DISPLAY TIME
01H–FFH : 1–255 minutes (1 min.–4 hrs. 15 min.)
DATA04
PROGRAM 2
01H : screen division 1
02H : screen division 4
03H : screen division 9
DATA05
SOURCE
01H : video 1
02H : video 2
03H : video 3
05H : COMPNT1
06H : COMPNT2 (SCART1/SCART2)
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
0DH : COMPNT3 (SCART3)
DATA06
DISPLAY TIME
01H–FFH : 1–255 minutes (1 min.–4 hrs. 15 min.)
ACK
7FH
60H
80H
64H
00H
CKS
* After executing AUTO ID, transmit this command.
* “SCART1, 2, 3” function is only PDP-61MXE1.
77. D-SUB INPUT
Function
The external control apparatus selects D-SUB INPUT of
the display.
Transmit Data
DFH
80H
60H
8DH
01H
DATA00
CKS
DATA00 : D-SUB INPUT
01H : RGB
02H : SCART3
ACK
7FH
60H
80H
8DH
01H
DATA00
CKS
DATA00 : D-SUB INPUT
01H : RGB
02H : SCART3
* “SCART3” function is only PDP-61MXE1.