22
2.4.2 Hanging on the wall
Carefully read the following before attempting to hang the unit on a wall, and observe the various limitations specified
below. Be sure to mount the unit so that twisting, bending, or any other deformation does not exceed 4 mm.
Ventilation Requirements for enclosure mounting
To allow heat to disperse, leave space between surrounding objects as shown on the diagram below when installing.
Special Instruction (Hanging on the wall)
Operating temperature restrictions
✩
Standard single-unit installation
Distance from wall (A)
B
C
D
Ambient temperature
50 mm or more
50 mm or more
50 mm or more
50 mm or more
0 to 40°C
✩
Requirements when used with PDP-S29-LR speaker system
Requirements are the same as those for standard single-unit installation.
However, dimensions refer to the distance between the speaker and the wall
D
D
C
B
Wall
Wall
A
Methods of Securing: Basic methods of securing are shown below. Avoid blocking or covering areas aside from those
indicated by
. Before attaching the unit to fittings, double-check that the thickness and height
of the fittings, and the number of fixing bolts is correct. (Also refer to 2.4.1 “Mounting to fittings
(pg. 21)”.)
Heated air is drawn off from the interior of the unit by fans. Before installation, consider the heat resistance of the wall
or other surfaces behind the unit. Exhaust temperatures can be 30 °C higher than the outside temperature.
For wall-mounting, do not bundle the cables in a way that will obstruct ventilation.
Note
Note