82
RS-232C Adjustment Mode
70. POWER DELAY ON
(for 4 screens and 9 screens)
Function
This external control apparatus turns on power to multiple
displays with a time lag.
Transmit Data
DFH
80H
60H
F2H
01H
DATA00
CKS
DATA00 : 00H–FFH : time lag time (seconds)
* This command is valid when the screen division setting is 1
screen, 4 screens, or 9 screens.
* This command is premised on the system configuration of the
multiple displays being a multi-system. The master OSD
operation command is issued when the value of DATA is 01H
(1 second). Because this command is a one-way command,
there is no ACK.
71. POWER DELAY ON
(for 16 screens and 25 screens)
Function
The external control apparatus turns on power to multiple
displays with a time lag.
Transmit Data
Function
External control apparatus attaches a time lag to 10 or more
plasma monitors, and turns on a power supply.
Transmission Data
DFH
80H
60H
F6H
01H
DATA00
CKS
DATA00 : 01H mode 1
02H mode 2
ACK
7FH
60H
80H
F6H
01H
DATA00
CKS
DATA00 : 01H mode 1
02H mode 2
* This command is effective only when the screen division setting
is 16 screens or 25 screens.
72. ORBITER SET
Function
This sets the picture shift function (*1).
It switches between PC Menu, Long Life, and Picture Shift.
Transmit Data
DFH
80H
60H
1EH
04H
DATA00–DATA03
CKS
DATA00 : mode
00H : off
01H : auto1
02H : auto2
03H : manual
DATA01 : quantity of horizontal shift
1 dot
: 01H
–
: –
20 dots
: 14H
DATA02 : quantity of vertical shift
1 line
: 01H
–
: –
0 lines
: 14H
DATA03 : shifting interval
1–5 minutes : 01H–05H
ACK
7FH
60H
80H
1EH
01H
DATA00
CKS
DATA00 : mode
00H : off
01H : auto1
02H : auto2
03H : manual
* DATA01–03
When auto1, 2 is set : setting 01H
When manual is set : setting is valid
73. OSM ANGLE
Function
It selects OSM vertical and horizontal displays.
Transmit Data
DFH
80H
60H
60H
01H
DATA00
CKS
DATA00
01H : horizontal display
02H : vertical display
ACK
7FH
60H
80H
60H
01H
DATA00
CKS
DATA00
01H : horizontal display
02H : vertical display