QUEST Command List
[QAP] Response format
[QST] Response format
[QST] Size information
[QST] Power supply state
Order
Data Contents
Value
Length
(BYTE)
1
STX
1
3
18
2
1
0x02
"QAP"
PDP-507CMX-JP
∗∗∗∗∗
PDP-507CMX
∗∗∗∗∗∗∗∗
PDP-50MXE20
∗∗∗∗∗∗∗
PDP-50MXE20-S
∗∗∗∗∗
PDP-607CMX
∗∗∗∗∗∗∗∗
50 J (Japan)
A (North America)
G (European/General included CKD)
GS (European/General-Silver)
A (North America)
G (European/General)
60
PDP-60MXE20
∗∗∗∗∗∗∗
(CS)
0x03
ETX
2
3
5
6
Order
Data Contents
Value
Length
(BYTE)
1
STX
1
3
1
1
1
1
1
1
3
0x02
"QST"
"7"
"M"
2
3
4
5
6
7
8
9
3
10
1
11
1
12
1
13
3
14
3
15
3
16
15
17
3
18
2
19
5
HOUR METER
Two-screen display state
20
2
(CS)
Check sum
Main input function
Generation information
Size information
Refer to following
Standby state/Energization state (refer to the following table)
Destination
Power supply state
At standby: standby factor
In electric conduction: Main-screen signal state
At standby: standby factor (refer to the following table)
In electric conduction: Main-screen signal state (refer to the following table)
Time data of the Hour Meter controlled by the Main microcomputer
If the time data of the Hour Meter are fewer than five digits, the higher-order
digits will be padded with zeros.
Sub-screen signal state
Echo back
Echo back
Model name information
Sub input function
Main screen size infromation
Dummy data 2
Dummy data 1
Serial number
Functional lock information
Temperature information 1 (inside)
Temperature information 2 (outside air)
Temperature information 3 (SLOT)
21
1
0x03
ETX
22
Sub-screen signal state (refer to the following table)
Input function of Main screen (refer to the following table)
Input function of Sub screen (refer to the following table)
Main screen size (refer to the following table)
Two-screen display state (refer to the following table)
Functional lock state (refer to the following table)
Main unit inside temperature (centigrade) (T2)
Outside air temperature (centigrade) (T3)
SLOT temperature (centigrade) (T5)
Serial number from the main micro computer
All "0"
All "
∗
"
Check sum
Factory
Normal Operation
QAP
QST
QS1
QS4
QPI
QWB
QPS
QSS
QSO
QCI
QSU
QSI
QS2
QIP
QAJ
QPW
QPM
QPD
QNG
QSD
Command Effectiveness
Command
Functional Description
"1"
"3"
Size information
(response)
"2"
"3"
"4"
"4"
"5"
"5"
"6"
"7"
"6"
"
∗
"
"S"
Standby state
Energization state
"P"
Power supply state
Power supply state
(response)
To acquired data on the MD microcomputer
Resolution / size information
The command QSI is for acquiring all data on input video signals.
The command QNG is for acquiring data on the history data (8 times) of the shut down information.
The command QS2 is for acquiring data on the panel's operational information.
The command QIP is for acquiring data on operational information of the panel.
The command QAJ is for acquiring the panel's factory-preset data.
The command QPW is for acquiring the factory-preset data about the video of the panel.
The command QPM is for acquiring the accumulated number of pulses of the panel.
The command QPD is for acquiring data from the 8 latest power-down (PD) logs.
Except the above
The command QSD is for acquiring the data from the 8 latest shutdown (SD) logs.
The command QAP is for acquiring data on the model name from the main micro-computer management
The command QST is for acquiring data on the product status
The command QS1 is for acquiring data on the various version information from the main micro-computer and module micro-computer management.
The command QS4 is for acquiring data on the input function, input signal information, screen size and destination information of the main screen.
The command QPI is for acquiring data on the integrator/PICTURE information.
The command QWB is for acquiring data on the integrator/WHITE BALANCE information.
The command QWS is for acquiring data on the integrator/SCREEN information.
The command QSS is for acquiring data on the Menu/integrator SETUP information.
The command QSO is for acquiring data on the Menu/integrator OPTION information.
The command QCI is for acquiring data on the time information from the main micro-computer management.
The command QSU is for acquiring data on the audio status.