8.4.1 PANEL INFORMATION
8.4.2 PANEL WORKS
• In the following examples, GUI images for a 50-inch model are indicated. Although the display areas for the menu for
42-inch and 50-inch models are different, the items to be displayed are the same.
Details of indications in each layer
• Data, such as the version of the microcomputer of the panel, product serial number, and statuses of memories for
adjustment values for the main unit and for backup, are displayed. No other layers are nested below this layer, and
there are no adjustment items.
MODULE : The version of data written in the Module microcomputer (IC3151) is indicated.
SEQ-PRG : The version of data written in the Sequence Program Storage Memory (IC3301) is indicated.
VD-SEQ
: The Drive Sequence version for Video mode is indicated.
PC-SEQ
: The Drive Sequence version for PC mode is indicated.
SERIAL
: The serial number of the module is indicated.
DIG.EEP
: The adjusted status of the EEPROM that is mounted on the DIGITAL Assy is indicated.
BACKUP : The adjusted status of the EEPROM for backup that is mounted on the SENSOR Assy is indicated.
<DOWN> : Shifting to PANEL WORKS
<UP>
: Shifting to COMBI MASK SETUP
(+)
<L/R>
: Updating displayed information
Key operation
Display items:
Display area for 42-inch model
Display area for 50-inch model
Contents of the Display item
• PM-B1 to B5: The accumulated pulse-meter counts for the 5 blocks on the screen are indicated.
(the lowest-order digit represents millions of pulses.)
• HR-MTR: The hour-meter value (accumulated power-on hours) is indicated.
• P-COUNT: The accumulated power-on count is indicated.
• TEMP1: The current panel temperature and the historical maximum temperature recorded in memory are indicated.
The range of temperature indication is from -50.0 to +99.9. (The temperature unit is "
°
C (Centigrade) ".)
• Data on operations, such as the accumulated pulse-meter counts, hour-meter count, power-on count, and temperature
detected by the sensor, are sent back. No other layers are nested below this layer, and there are no adjustment items.
<DOWN> : Shifting to POWER DOWN
<UP>
: Shifting to PANEL INFORMATION
<L/R>
: Updating displayed information
Key operation
A
.
P
N E L
A
P
N E L
O
W
R K S
M
P
– B 1
0 0 0
0
0
M
P
– B 2
0 0 0
0
0
7
5
1
6
7
M
M
0
0 0 0
0
0
0 0 0
0
0
8
2
5
6
8
M
M
6
0 0 0
0
0
7
3
M
3
0 0 0
2
0
5
0 M
2
H
M
P
– B 3
M
P
– B 4
M
P
– B 5
–
P
C O U
T
N
0 0 0
0
0
0
5
9
I
T
M
S
E
E
T
M P 1
+ 2
4
.
7
+ 7
8
.
0
/
R
H
– M T R
F A C T
I
–
N 1
3
2
0 6 0
– R G B
W
J
–
M 7
1
5
10
15
16
1
5
10
15
20
25
30
32
1
2
3
4
5
6
7
8
9
A
B
C
D
E
AREA
Temperature unit is "
°
C (Centigrade) ".
Summary of Contents for PDP 507CMX
Page 44: ...PDP 507CMX 44 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Page 45: ...PDP 507CMX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Page 84: ...PDP 507CMX 84 1 2 3 4 1 2 3 4 C D F A B E 500ns div 500ns div 200ns div ...
Page 104: ...PDP 507CMX 104 1 2 3 4 1 2 3 4 C D F A B E ...