PDP-507CMX
135
5
6
7
8
5
6
7
8
C
D
F
A
B
E
7.3 HOW TO CLEAR HISTORY DATA
About clearing log data after an Assy replacement
In the backup EEPROM of the DIGITAL Assy, besides adjustment values of the main unit, data on power-on time and log data
on defective parts, etc. are updated and stored. Among those data, some need to be cleared when the DIGITAL Assy is
replaced during servicing.
(1) To clear the data using RS-232C commands, first send the FAY command to enter Factory mode, then send a command
shown in the table above.
(2) To clear the data using the Factory menu, first display the Factory menu by pressing the keys in the following step:
Press
DISPLAY
key
→
Don't press any keys for 3 seconds
→
Press the keys in the following order:
LEFT
,
UP
,
LEFT
,
RIGHT
, then
POWER
.
PANEL INFORMATION
ETC (+)
(down)
(down)
(down)
(down)
SET
BACKUP DATA
DIGITAL EEPROM
Item
Content
Services
RS-232C
Command
Panel
replacement
Power unit
replacement
Other than
those at left
Hour meter
Accumulated display time
Clearing required
Clearing not
required
Clearing not
required
CHM
Shutdown logs
Location where an SD was generated
and the hour-meter value at that time
Clearing required
Clearing not
required
Clearing not
required
CSD
Power-down logs
Location where a PD was generated
and the hour-meter value at that time
Clearing required
Clearing not
required
Clearing not
required
CPD
Pulse meter
Accumulated number of pulse emissions
(Block 5)
Clearing required
Clearing not
required
Clearing not
required
CPM
Power-on count
Accumulated RELAY_ON counts
Clearing not
required
Clearing required
Clearing not
required
CPC
MAX TEMP
In the past the greatest temperature
Clearing required
Clearing required
Clearing required
CMT
PD INFO: NO OPRT
PD INFO: CLEAR
(down)
SET (Hold the keys pressed for 5 seconds.)
(right)
To clear PD logs
SD INFO: NO OPRT
SD INFO: CLEAR
(down)
SET (Hold the keys pressed for 5 seconds.)
(right)
To clear SD logs
HR-MTR INFO: NO OPRT
HR-MTR INFO: CLEAR
(down)
SET (Hold the keys pressed for 5 seconds.)
(right)
To clear hour meter data
PM/B1-B5 INFO: NO OPRT
PM/B1-B5 INFO: CLEAR
(down)
SET (Hold the keys pressed for 5 seconds.)
(right)
To clear pulse meter data
P COUNT INFO: NO OPRT
MAX TEMP : NO OPRT
P COUNT INFO: CLEAR
(down)
SET (Hold the keys pressed for 5 seconds.)
MAX TEMP : CLEAR
SET (Hold the keys pressed for 5 seconds.)
(right)
To clear power-on-count data
To clear MAX TEMP
(right)
Summary of Contents for PDP 507CMX
Page 44: ...PDP 507CMX 44 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL CONNECTION DIAGRAM 2 2 ...
Page 45: ...PDP 507CMX 45 5 6 7 8 5 6 7 8 C D F A B E ...
Page 84: ...PDP 507CMX 84 1 2 3 4 1 2 3 4 C D F A B E 500ns div 500ns div 200ns div ...
Page 104: ...PDP 507CMX 104 1 2 3 4 1 2 3 4 C D F A B E ...