Factory related command
Command
Operation
Command Effectiveness
Numeric Direct input
Remarks
Factory
Normal
Operation
Validity
Minimum
Maximum
Operation mode selection
FAN
Turning the factory mode OFF
O
-
-
-
-
FAY
Turning the factory mode ON
-
O
-
-
-
FALS00
Turning the factory mode lock OFF
O
-
-
-
-
FALS01
Turning the factory mode ON
O
-
-
-
-
Power supply control of drive system
DRVS00
Turning the power of drive system OFF
O
O
-
-
-
DRVS01
Turning the power of drive system ON
O
O
-
-
-
Various adjustment of the main side
MAJS00
Starting the W/B and LPF auto adjustment of the MAIN Assy
O
-
-
-
-
MAJS01
Forcibly finishing the W/B and LPF auto adjustment of the MAIN Assy
O
-
-
-
-
ADC***
Adjusting the AD contrast
O
-
O
000
255
MRG***
Adjusting the R GAIN of AD MAIN
O
-
O
000
255
MRO***
Adjusting the R OFFSET of AD MAIN
O
-
O
000
255
MGG***
Adjusting the G GAIN of AD MAIN
O
-
O
000
255
MGO***
Adjusting the G OFFSET of AD MAIN
O
-
O
000
255
MBG***
Adjusting the B GAIN of AD MAIN
O
-
O
000
255
MBO***
Adjusting the B OFFSET of AD MAIN
O
-
O
000
255
SRG***
Adjusting the R GAIN of AD SUB
O
-
O
000
255
SRO***
Adjusting the R OFFSET of AD SUB
O
-
O
000
255
SGG***
Adjusting the G GAIN of AD SUB
O
-
O
000
255
SGO***
Adjusting the G OFFSET of AD SUB
O
-
O
000
255
SBG***
Adjusting the B GAIN of AD SUB
O
-
O
000
255
SBO***
Adjusting the B OFFSET of AD SUB
O
-
O
000
255
Various control of the main side
FCNS00
Setting the fan roll control to stop
O
-
-
-
-
FCNS01
Setting the fan roll control to maximum
O
-
-
-
-
FCNS02
Setting the fan roll control to middle
O
-
-
-
-
FCNS03
Setting the fan roll control to weak
O
-
-
-
-
FCNS04
Setting the fan roll control to auto
O
-
-
-
-
FCNS99
Setting the fan roll control to TEST
O
-
-
-
-
FOF
Requesting the fan abnormality detection
O
-
-
-
-
LEDS00
Turning off the all front indicators
O
-
-
-
-
LEDS02
Setting the front indicators to normal operation
O
-
-
-
-
LEDS10
Front indicators: ON (green)
O
-
-
-
-
LEDS11
Front indicators: STANDBY (red)
O
-
-
-
-
EDWS00
Prohibiting writing of EDID data
O
-
-
-
-
EDWS01
Permitting writing of EDID data
O
-
-
-
-
EPAS00
Prohibiting EEPROM access from the outside
O
-
-
-
-
EPAS01
Permitting EEPROM access from the outside
O
-
-
-
-
ACK
→
S01 : Normal
S02 : Abnormal