Controller
148
Electrical Control System
8. Adjust button: Set indoor temperature up. If press and hold on, it will increase at 1degree per 0.5
second.
9. Adjust button: Set indoor temperature down. if press and hold on, it will decrease at 1degree per 0.5
Second.
10. Swing button: First press, start swing function; second press, stop swing. (Match to some model with
swing function).
11. Economy operation button: press this button, the indoor unit operates in economy mode, press again,
exit this mode (it may be ineffective for some models)
12. Fan speed button: press this button consecutively; the fan speed will circle as follow:
13. Lock button (hidden): When you push the LOCK button, all current settings are locked in and the wire
controller does not accept any operation except that of the LOCK button. Use the lock mode when you
want to prevent setting from being changed accidentally or play fully. Push the LOCK button again when
you want to cancel the LOCK mode.
Name and function of LCD on the wire
controller
1. Operation mode indication: When press” MODE” button, the following mode can be selected in circle.
Auto Cool Dry Heat Fan only Auto.
Auto
→
Cool
→
Dry
→
Heat
→
Fan only
→
Auto
For cooling only model, heat mode is skipped.
2. Timer: When adjust setting on time or only on time is set, the “ON” is lighted. When adjust setting off
time or only off time is set, the” OFF" is lighted. If on and off timer are both set, the “ON” and “OFF” are
both lighted.
3. Follow me function: There is a temperature sensor inside the wire controller, after setting temperature, it
will compare the two temperatures, and the space of wire controller will be the same as setting
temperature. It is available under cooling, heating, auto mode.
4
ON/OFF indication: When it is on, the icon display, otherwise it is extinguished.
5. Fan speed indication: There are four fan modes: low, middle, high, auto. For some models, no middle
fan then the middle fan is seen as high speed.
6. Lock: When the "LOCK" button is pressed, the icon appears and other buttons is unable, press again,
the icon disappears.
7. Temperature display zone: Generally it displays setting temperature; it can be adjusted by press
temperature button
▲
and
▼
.But in fan mode, no display here.
Remark:
Summary of Contents for LISAS-B-1403
Page 10: ...Features 12K 18K 8 Indoor Units ...
Page 15: ...Features 24K 36K Indoor Units 13 ...
Page 18: ...Service Space 16 Indoor Units 4 Service Space ...
Page 31: ...Wiring Diagrams Indoor Units 29 ...
Page 46: ...Wiring Diagrams 44 Indoor Units 4 Wiring Diagrams UB012GMFI16MLD UB018GMFI16MLD ...
Page 47: ...Wiring Diagrams Indoor Units 45 UB024GMFI16MLD UB036GMFI16MLD UB048GMFI16MLD ...
Page 52: ......
Page 55: ...Dimensions Indoor Units 53 2 Dimensions 16 Drain pipe 195 Hanging arm Unit mm 700 600 210 ...
Page 56: ...Service Space 54 Indoor Units 3 Service Space ...
Page 57: ...Wiring Diagrams Indoor Units 55 4 Wiring Diagrams FB012GMFI16MLD ...
Page 61: ...Field Wiring Indoor Units 59 9 Field Wiring MFAU 12HRFN1 M ...
Page 67: ...Wiring Diagrams Outdoor Units 65 4 Wiring Diagrams YN012GMFI16RUD YN018GMFI16RUD ...
Page 68: ...Wiring Diagrams 66 Outdoor Units YN024GMFI16RUD ...
Page 69: ...Wiring Diagrams Outdoor Units 67 YN036GMFI16RUD YN048GMFI16RUD ...
Page 125: ...Troubleshooting Electrical Control System 123 2 4 1 2 Outdoor unit malfunction ...
Page 131: ...Troubleshooting Electrical Control System 129 2 4 4 3 E2 malfunction Only for 12 18K ...
Page 132: ...Troubleshooting 130 Electrical Control System 2 4 4 4 E2 malfunction For 24 48K ...
Page 133: ...Troubleshooting Electrical Control System 131 2 4 4 5 E3 malfunction ...
Page 134: ...Troubleshooting 132 Electrical Control System 2 4 4 6 E4 malfunction ...
Page 136: ...Troubleshooting 134 Electrical Control System 2 4 4 8 E6 malfunction Only for 36K 48K ...
Page 138: ...Troubleshooting 136 Electrical Control System 2 4 4 10 P1 malfunction Only for 36K 48K ...
Page 139: ...Troubleshooting Electrical Control System 137 2 4 4 11 P2 malfunction Only for 36K 48K ...
Page 140: ...Troubleshooting 138 Electrical Control System 2 4 4 12 P3 malfunction ...