Troubleshooting
120
Electrical Control System
For 36K~48K Units
NO.
Malfunction
Defrosting
lamp
Alarm
lamp
Running lamp
Timer
lamp
Display(digital
tube)
1
Communication malfunction between indoor
and outdoor units.
X
X
X
☆
E1
2
Open or short circuit of T1 temperature
sensor
X
X
☆
X
E2
3
Open or short circuit of T2 temperature
sensor
X
X
☆
X
E3
4
Open or short circuit of T2B temperature
sensor
X
X
☆
X
E4
5
Indoor EEPROM malfunction
☆
X
X
X
E7
6
Indoor fan speed is out of control
☆
☆
X
X
E8
7
Refrigerant Leakage Detection
☆
☆
O
X
EC
8
Outdoor unit malfunction
X
◎
X
X
Ed
9
Full-water malfunction
X
☆
X
X
EE
10
Communication malfunction between main
PCB and up-down panel PCB
☆
☆
☆
X
F0
11
Up-down panel malfunction
☆
☆
X
☆
F1
12
Up-down panel is not closed
☆
☆
X
O
F2
O (on) X(off)
☆
(flash at 5Hz)
◎
(flash at 0.5Hz)
F0,F1,F2 is only available for super-slim cassette
2.3 Outdoor unit malfunction
For YN012GMFI16RUD and YN018GMFI18RUD:
No.
Problems
Green
Red
IU display
1
standby for normal
O
X
2
Operation normally
X
O
3
IPM malfunction or IGBT over-strong current protection
☆
X
P0
4
Over voltage or too low voltage protection
O
O
P1
5
Inverter compressor drive error
X
☆
P4
6
Inverter compressor drive error
☆
O
P4
7
Communication malfunction between compressor driver board and
outdoor main board
☆
☆
P4
8
Compressor driver board EEPROM malfunction
O
☆
E5
O
(
light
)
X
(
off
)
☆(
2.5Hz flash
)
Summary of Contents for LISAS-B-1403
Page 10: ...Features 12K 18K 8 Indoor Units ...
Page 15: ...Features 24K 36K Indoor Units 13 ...
Page 18: ...Service Space 16 Indoor Units 4 Service Space ...
Page 31: ...Wiring Diagrams Indoor Units 29 ...
Page 46: ...Wiring Diagrams 44 Indoor Units 4 Wiring Diagrams UB012GMFI16MLD UB018GMFI16MLD ...
Page 47: ...Wiring Diagrams Indoor Units 45 UB024GMFI16MLD UB036GMFI16MLD UB048GMFI16MLD ...
Page 52: ......
Page 55: ...Dimensions Indoor Units 53 2 Dimensions 16 Drain pipe 195 Hanging arm Unit mm 700 600 210 ...
Page 56: ...Service Space 54 Indoor Units 3 Service Space ...
Page 57: ...Wiring Diagrams Indoor Units 55 4 Wiring Diagrams FB012GMFI16MLD ...
Page 61: ...Field Wiring Indoor Units 59 9 Field Wiring MFAU 12HRFN1 M ...
Page 67: ...Wiring Diagrams Outdoor Units 65 4 Wiring Diagrams YN012GMFI16RUD YN018GMFI16RUD ...
Page 68: ...Wiring Diagrams 66 Outdoor Units YN024GMFI16RUD ...
Page 69: ...Wiring Diagrams Outdoor Units 67 YN036GMFI16RUD YN048GMFI16RUD ...
Page 125: ...Troubleshooting Electrical Control System 123 2 4 1 2 Outdoor unit malfunction ...
Page 131: ...Troubleshooting Electrical Control System 129 2 4 4 3 E2 malfunction Only for 12 18K ...
Page 132: ...Troubleshooting 130 Electrical Control System 2 4 4 4 E2 malfunction For 24 48K ...
Page 133: ...Troubleshooting Electrical Control System 131 2 4 4 5 E3 malfunction ...
Page 134: ...Troubleshooting 132 Electrical Control System 2 4 4 6 E4 malfunction ...
Page 136: ...Troubleshooting 134 Electrical Control System 2 4 4 8 E6 malfunction Only for 36K 48K ...
Page 138: ...Troubleshooting 136 Electrical Control System 2 4 4 10 P1 malfunction Only for 36K 48K ...
Page 139: ...Troubleshooting Electrical Control System 137 2 4 4 11 P2 malfunction Only for 36K 48K ...
Page 140: ...Troubleshooting 138 Electrical Control System 2 4 4 12 P3 malfunction ...