DV-59AVi
105
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Front side
Note:
Be sure to move the Pickup Assy-S to the innermost perimeter.
: Conductive surface
Arrangement of the flexible cable for the pickup
2
2
1
3
7
Attach the flexible cable of the pickup to the connector.
1
Fold the flexible cable inward at the position of the reference
line.
3
Fold the flexible cable of the pickup with the backing inward.
7
Pass the flexible cable below the hook, and fold it back.
8
Fold the flexible cable back at the hook.
9
Fold the flexible cable along the hook.
4
Pass the flexible cable through the hook not allowing
any slack.
6
Hook the part folded in Step
1
to the hook.
5
Fold the flexible cable as indicated in the photo.
Hook
Bottom view
5
6
Make sure there is no slack in the cable
Reference line
Reference line
Backing
97mm
±
2mm
Reference
line
Hook
Pass the cable below the hook
Hook
8
Hook
Hook
9
Make sure that the cable does not have any slack
Make sure that the cable is loose
4