19. Take out DVD GGV1025.
Insert CD TCD-782.
20. Set the mecha.
21. Adjustment of the initial position of VR for Power adjustment
22. Set DISC TYPE to CD.
23. Power on.
24. Execute until Focus Close 1 is reached.
If the waveform is similar to RF waveform after Focus Close and Tracking Open (waveform measured by analog oscilloscope), Focus Close is reached.
Go to STEP 20.
If the RF waveform does not appear, Focus Close is not reached. Return to STEP 21 and change the angle of initial position of CD VR (VR1101).
If Focus Close is not reached after the 3rd VR adjustment, replace the Mechanism Unit (Service).
25. Conduct Power adjustment. (Conduct the adjustment in the state of Focus Close.)
26. Execute until Tracking Close is reached.
27. Conduct Power adjustment. (Conduct the adjustment in the state of Focus Close.)
28. Check ERR rate.
29. Power off.
30. Return to the original position.
31. Set up again (setting of CD layer), and conduct the final check of RF level and ERR rate.
(Check in the state of Tracking Close)
32. Eject.
33. Take out CD TCD-782.
34. Power off.
Adjust the angle at the D cut position to the initial position
(initial position shown in Fig.2).
1st
2nd
3rd
CD
(VR1101)
-30°
-45°
-90°
DVD (VR1102)
CD
CD
CD
CD
CD
528 mV to 832 mV
1.0E – 2 and under
200 mV to 1200 mV
658 mV to 702 mV
As the adjustment is
completed, never change.
0°
0°
CD VR (VR1101)
Adjustment of the initial position
1st - 30°
DVD VR (VR1102)
As the adjustment is
completed, never change.
3rd - -90°
2nd - -45°
1.0E – 2 and under
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Fig.2