35
CX-3311
5
6
7
8
5
6
7
8
A
B
C
D
E
F
Check 3: Reset OK?
<Check> Check the voltage at the “NRES” test point while the power is on.
Check the “DGND1” test point at the reference.
No.
Check point
Module No.
Specification value
Unit
1
NRES - DGND1
ALL
VCC33 - 0.7 or more
V
Side A
Fig 3.1: Reset check point
NRES
DGND1