60
Sentinel & PimaGuard
Installation Guide
A
PPENDIX
F P
ROGRAMMING
L
INE
& R
ADIO
F
ORMATS
Line Formats
System
PAF/NPAF/EPAF/PID, DESK . If the system’s ContactID=1, the account is in Hex.
Flags
Additional 35.8 mlSec, for pulse protocol in 143mlSec
Radio Formats
System
KP5
bit7...bit2 -5-th byte, b2...b1 – system (b11...b10)
All other system formats are as is
Flags
bit0 - Account BIN
bit1 - Account MSB BIN
bit2 - Account MSB to LSB
bit3 - bit15 is part of Account
bit4 - INTRAC2000 Event Unary/VISONIC2000 bit16 part of Event
bit5 - Parity invert (ODD)
bit6 - Enable bit0 in PAF System
bit7 - SYNC OFF required
Extra
bit0 - bit0 value
bit1 - bit24 (INTRAC2000)/bit10 (MILCOLD) value
bit2 - bit25 (INTRAC2000)/bit11 (MILCOLD, DESK) value
bit3 - spare value
bit4 - bit0 mask
bit5 - bit24 (INTRAC2000)/bit10 (MILCOLD) mask
YK
Communications
Restoral
TRANSMITTER has resumed communication with a RECEIVER
Unused
YM
System Battery
Missing
TRANSMITTER/RECEIVER battery is missing
Unused
YN
Invalid Report
TRANSMITTER has sent a packet with invalid data
Unused
YO
Unknown Message
An unknown message was received from automation or the
printer
Unused
YP
Power Supply
Trouble
TRANSMITTER/RECEIVER has a problem with the power supply
Unused
YQ
Power Supply
Restored
TRANSMITTER’S/RECEIVER’S power supply has been restored
Unused
YR
System Battery
Restoral
Low battery has been corrected
Unused
YS
Communications
Trouble
RECEIVER and TRANSMITTER
Unused
YT
System Battery
Trouble
Low battery in control/communicator
Unused
YU
Diagnostic Error
An expansion/peripheral device is reporting a diagnostic error
Condition number
YW
Watchdog Reset
The TRANSMITTER created an internal reset
Unused
YX
Service Required
A TRANSMITTER/RECEIVER needs service
Unused
YY
Status Report
This is a header for an account status report transmission
Unused
YZ
Service Completed
Required TRANSMITTER / RECEIVER service completed
Mfr defined
ZA
Freeze Alarm
Low temperature detected at premises
Zone or point
ZB
Freeze Bypass
Low temperature detection has been bypassed
Zone or point
ZH
Freeze Alarm
Restore
Alarm condition eliminated
Zone or point
ZJ
Freeze Trouble
Restore
Trouble condition eliminated
Zone or point
ZR
Freeze Restoral
Alarm/trouble condition has been eliminated
Zone or point
ZS
Freeze Supervisory
Unsafe freeze detection system condition
Zone or point
ZT
Freeze Trouble
Zone disabled by fault
Zone or point
ZU
Freeze Unbypass
Low temperature detection bypass removed
Zone or point
Data Code Short Description
Long Description
Address Field